Warning! Notes: Case: Winchester; twist: 1:10"; primer: Winchester LRM, Large Rifle Magnum; barrel length: 24"; trim length: 2.090"; bullet diam.: 0.323".
Be Alert: Publisher cannot be responsible for errors in published load data.
Wt. Bullet Powder Manufacturer Powder Charge Velocity (FPS)
150 Hornady SP Hodgdon H-4831 Subscribe 2945
Remarks: start load; COL: 2.810"; 44,100 psi
150 Hornady SP Hodgdon H-4831 Subscribe 3115
Remarks: max load; compressed; COL: 2.810"; 52,800 psi
150 Hornady SP IMR IMR-4831 Subscribe 2960
Remarks: start load; COL: 2.810"; 49,300 psi
150 Hornady SP IMR IMR-4831 Subscribe 3162
Remarks: max load; compressed; COL: 2.810"; 59,700 psi
150 Hornady SP Hodgdon H-4350 Subscribe 3138
Remarks: start load; COL: 2.810"; 51,600 psi
150 Hornady SP Hodgdon H-4350 Subscribe 3345
Remarks: max load; compressed; COL: 2.810"; 63,700 psi
150 Hornady SP Hodgdon H-414 Subscribe 3217
Remarks: start load; COL: 2.810"; 54,600 psi
150 Hornady SP Hodgdon H-414 Subscribe 3360
Remarks: max load; COL: 2.810"; 63,100 psi
150 Hornady SP IMR IMR-4350 Subscribe 3008
Remarks: start load; COL: 2.810"; 50,100 psi
150 Hornady SP IMR IMR-4350 Subscribe 3198
Remarks: max load; COL: 2.810"; 61,500 psi
150 Hornady SP Winchester W-760 Subscribe 3217
Remarks: start load; COL: 2.810"; 54,600 psi
150 Hornady SP Winchester W-760 Subscribe 3360
Remarks: max load; COL: 2.810"; 63,100 psi
150 Hornady SP Hodgdon H-380 Subscribe 3174
Remarks: start load; COL: 2.810"; 53,600 psi
150 Hornady SP Hodgdon H-380 Subscribe 3336
Remarks: max load; COL: 2.810"; 62,500 psi
150 Hornady SP Hodgdon Varget Subscribe 3137
Remarks: start load; COL: 2.810"; 54,200 psi
150 Hornady SP Hodgdon Varget Subscribe 3305
Remarks: max load; COL: 2.810"; 63,600 psi
150 Hornady SP IMR IMR-4320 Subscribe 3012
Remarks: start load; COL: 2.810"; 52,200 psi
150 Hornady SP IMR IMR-4320 Subscribe 3171
Remarks: max load; COL: 2.810"; 61,500 psi
150 Hornady SP IMR IMR-4064 Subscribe 3076
Remarks: start load; COL: 2.810"; 53,600 psi
150 Hornady SP IMR IMR-4064 Subscribe 3207
Remarks: max load; COL: 2.810"; 61,100 psi
150 Hornady SP Hodgdon BL-C(2) Subscribe 3190
Remarks: start load; COL: 2.810"; 53,500 psi
150 Hornady SP Hodgdon BL-C(2) Subscribe 3362
Remarks: max load; COL: 2.810"; 63,300 psi
150 Hornady SP IMR IMR-4895 Subscribe 3075
Remarks: start load; COL: 2.810"; 53,900 psi
150 Hornady SP IMR IMR-4895 Subscribe 3245
Remarks: max load; COL: 2.810"; 63,100 psi
150 Hornady SP Hodgdon H-4895 Subscribe 3156
Remarks: start load; COL: 2.810"; 53,600 psi
150 Hornady SP Hodgdon H-4895 Subscribe 3313
Remarks: max load; COL: 2.810"; 63,300 psi
150 Hornady SP IMR IMR-8208 XBR Subscribe 3059
Remarks: start load; COL: 2.810"; 55,400 psi
150 Hornady SP IMR IMR-8208 XBR Subscribe 3171
Remarks: max load; COL: 2.810"; 61,000 psi
150 Hornady SP IMR IMR-3031 Subscribe 3027
Remarks: start load; COL: 2.810"; 52,600 psi
150 Hornady SP IMR IMR-3031 Subscribe 3184
Remarks: max load; COL: 2.810"; 62,200 psi
150 Hornady SP Hodgdon Benchmark Subscribe 3074
Remarks: start load; COL: 2.810"; 50,200 psi
150 Hornady SP Hodgdon Benchmark Subscribe 3253
Remarks: max load; COL: 2.810"; 62,400 psi
175 Sierra SP Hodgdon H-4831 Subscribe 2819
Remarks: start load; COL: 2.855"; 51,400 psi
175 Sierra SP Hodgdon H-4831 Subscribe 2960
Remarks: max load; compressed; COL: 2.855"; 61,400 psi
175 Sierra SP IMR IMR-4831 Subscribe 2798
Remarks: start load; COL: 2.855"; 50,300 psi
175 Sierra SP IMR IMR-4831 Subscribe 2996
Remarks: max load; compressed; COL: 2.855"; 61,900 psi
175 Sierra SP Hodgdon H-4350 Subscribe 2835
Remarks: start load; COL: 2.855"; 51,100 psi
175 Sierra SP Hodgdon H-4350 Subscribe 3024
Remarks: max load; compressed; COL: 2.855"; 63,400 psi
175 Sierra SP Hodgdon H-414 Subscribe 2874
Remarks: start load; COL: 2.855"; 53,600 psi
175 Sierra SP Hodgdon H-414 Subscribe 3025
Remarks: max load; COL: 2.855"; 62,000 psi
175 Sierra SP IMR IMR-4350 Subscribe 2820
Remarks: start load; COL: 2.855"; 51,100 psi
175 Sierra SP IMR IMR-4350 Subscribe 3011
Remarks: max load; compressed; COL: 2.855"; 62,000 psi
175 Sierra SP Winchester W-760 Subscribe 2874
Remarks: start load; COL: 2.855"; 53,600 psi
175 Sierra SP Winchester W-760 Subscribe 3025
Remarks: max load; COL: 2.855"; 62,000 psi
175 Sierra SP Hodgdon H-380 Subscribe 2857
Remarks: start load; COL: 2.855"; 54,100 psi
175 Sierra SP Hodgdon H-380 Subscribe 2994
Remarks: max load; COL: 2.855"; 61,800 psi
175 Sierra SP Hodgdon Varget Subscribe 2862
Remarks: start load; COL: 2.855"; 55,400 psi
175 Sierra SP Hodgdon Varget Subscribe 2975
Remarks: max load; COL: 2.855"; 62,300 psi
175 Sierra SP IMR IMR-4320 Subscribe 2801
Remarks: start load; COL: 2.855"; 52,200 psi
175 Sierra SP IMR IMR-4320 Subscribe 2960
Remarks: max load; COL: 2.855"; 61,500 psi
175 Sierra SP IMR IMR-4064 Subscribe 2812
Remarks: start load; COL: 2.855"; 51,900 psi
175 Sierra SP IMR IMR-4064 Subscribe 2976
Remarks: max load; COL: 2.855"; 61,800 psi
175 Sierra SP Hodgdon BL-C(2) Subscribe 2870
Remarks: start load; COL: 2.855"; 54,100 psi
175 Sierra SP Hodgdon BL-C(2) Subscribe 3030
Remarks: max load; COL: 2.855"; 62,800 psi
175 Sierra SP IMR IMR-4895 Subscribe 2848
Remarks: start load; COL: 2.855"; 53,000 psi
175 Sierra SP IMR IMR-4895 Subscribe 3002
Remarks: max load; COL: 2.855"; 62,400 psi
175 Sierra SP Hodgdon H-4895 Subscribe 2858
Remarks: start load; COL: 2.855"; 54,100 psi
175 Sierra SP Hodgdon H-4895 Subscribe 3000
Remarks: max load; COL: 2.855"; 62,900 psi
175 Sierra SP IMR IMR-8208 XBR Subscribe 2793
Remarks: start load; COL: 2.855"; 54,300 psi
175 Sierra SP IMR IMR-8208 XBR Subscribe 2923
Remarks: max load; COL: 2.855"; 62,800 psi
175 Sierra SP IMR IMR-3031 Subscribe 2791
Remarks: start load; COL: 2.855"; 53,200 psi
175 Sierra SP IMR IMR-3031 Subscribe 2923
Remarks: max load; COL: 2.855"; 62,300 psi
175 Sierra SP Hodgdon Benchmark Subscribe 2743
Remarks: start load; COL: 2.855"; 54,000 psi
175 Sierra SP Hodgdon Benchmark Subscribe 2863
Remarks: max load; COL: 2.855"; 62,700 psi
180 Nosler BT Hodgdon H-4831 Subscribe 2776
Remarks: start load; COL: 2.840"; 52,900 psi
180 Nosler BT Hodgdon H-4831 Subscribe 2930
Remarks: max load; compressed; COL: 2.840"; 62,800 psi
180 Nosler BT Hodgdon Hybrid 100V Subscribe 2768
Remarks: start load; COL: 2.840"; 51,700 psi
180 Nosler BT Hodgdon Hybrid 100V Subscribe 2936
Remarks: max load; compressed; COL: 2.840"; 59,200 psi
180 Nosler BT IMR IMR-4831 Subscribe 2727
Remarks: start load; COL: 2.840"; 51,400 psi
180 Nosler BT IMR IMR-4831 Subscribe 2927
Remarks: max load; compressed; COL: 2.840"; 61,100 psi
180 Nosler BT Hodgdon H-4350 Subscribe 2794
Remarks: start load; COL: 2.840"; 52,500 psi
180 Nosler BT Hodgdon H-4350 Subscribe 2957
Remarks: max load; COL: 2.840"; 62,200 psi
180 Nosler BT Hodgdon H-414 Subscribe 2808
Remarks: start load; COL: 2.840"; 54,400 psi
180 Nosler BT Hodgdon H-414 Subscribe 2946
Remarks: max load; COL: 2.840"; 62,000 psi
180 Nosler BT IMR IMR-4350 Subscribe 2726
Remarks: start load; COL: 2.840"; 52,500 psi
180 Nosler BT IMR IMR-4350 Subscribe 2954
Remarks: max load; compressed; COL: 2.840"; 62,500 psi
180 Nosler BT Winchester W-760 Subscribe 2808
Remarks: start load; COL: 2.840"; 54,400 psi
180 Nosler BT Winchester W-760 Subscribe 2946
Remarks: max load; COL: 2.840"; 62,000 psi
180 Nosler BT Hodgdon H-380 Subscribe 2782
Remarks: start load; COL: 2.840"; 54,800 psi
180 Nosler BT Hodgdon H-380 Subscribe 2925
Remarks: max load; COL: 2.840"; 63,100 psi
180 Nosler BT Hodgdon Varget Subscribe 2770
Remarks: start load; COL: 2.840"; 56,500 psi
180 Nosler BT Hodgdon Varget Subscribe 2873
Remarks: max load; COL: 2.840"; 62,700 psi
180 Nosler BT IMR IMR-4320 Subscribe 2702
Remarks: start load; COL: 2.840"; 51,900 psi
180 Nosler BT IMR IMR-4320 Subscribe 2896
Remarks: max load; COL: 2.840"; 62,900 psi
180 Nosler BT IMR IMR-4064 Subscribe 2689
Remarks: start load; COL: 2.840"; 50,100 psi
180 Nosler BT IMR IMR-4064 Subscribe 2865
Remarks: max load; COL: 2.840"; 60,100 psi
180 Nosler BT Hodgdon BL-C(2) Subscribe 2792
Remarks: start load; COL: 2.840"; 55,400 psi
180 Nosler BT Hodgdon BL-C(2) Subscribe 2936
Remarks: max load; COL: 2.840"; 62,300 psi
180 Nosler BT IMR IMR-4895 Subscribe 2781
Remarks: start load; COL: 2.840"; 55,500 psi
180 Nosler BT IMR IMR-4895 Subscribe 2906
Remarks: max load; COL: 2.840"; 62,700 psi
180 Nosler BT Hodgdon H-4895 Subscribe 2732
Remarks: start load; COL: 2.840"; 55,100 psi
180 Nosler BT Hodgdon H-4895 Subscribe 2820
Remarks: max load; COL: 2.840"; 60,300 psi
180 Nosler BT IMR IMR-8208 XBR Subscribe 2743
Remarks: start load; COL: 2.840"; 54,900 psi
180 Nosler BT IMR IMR-8208 XBR Subscribe 2855
Remarks: max load; COL: 2.840"; 60,800 psi
195 Hornady SP IMR IMR-7828 Subscribe 2681
Remarks: start load; COL: 2.855"; 53,500 psi
195 Hornady SP IMR IMR-7828 Subscribe 2860
Remarks: max load; compressed; COL: 2.855"; 63,800 psi
195 Hornady SP Hodgdon H-4831 Subscribe 2704
Remarks: start load; COL: 2.855"; 54,600 psi
195 Hornady SP Hodgdon H-4831 Subscribe 2835
Remarks: max load; compressed; COL: 2.855"; 63,000 psi
195 Hornady SP Hodgdon Hybrid 100V Subscribe 2693
Remarks: start load; COL: 2.855"; 51,600 psi
195 Hornady SP Hodgdon Hybrid 100V Subscribe 2857
Remarks: max load; compressed; COL: 2.855"; 59,300 psi
195 Hornady SP IMR IMR-4831 Subscribe 2726
Remarks: start load; COL: 2.855"; 53,400 psi
195 Hornady SP IMR IMR-4831 Subscribe 2905
Remarks: max load; compressed; COL: 2.855"; 63,100 psi
195 Hornady SP Hodgdon H-4350 Subscribe 2712
Remarks: start load; COL: 2.855"; 54,400 psi
195 Hornady SP Hodgdon H-4350 Subscribe 2837
Remarks: max load; COL: 2.855"; 62,300 psi
195 Hornady SP Hodgdon H-414 Subscribe 2722
Remarks: start load; COL: 2.855"; 54,500 psi
195 Hornady SP Hodgdon H-414 Subscribe 2847
Remarks: max load; COL: 2.855"; 61,800 psi
195 Hornady SP IMR IMR-4350 Subscribe 2678
Remarks: start load; COL: 2.855"; 52,200 psi
195 Hornady SP IMR IMR-4350 Subscribe 2866
Remarks: max load; COL: 2.855"; 62,300 psi
195 Hornady SP Winchester W-760 Subscribe 2722
Remarks: start load; COL: 2.855"; 54,500 psi
195 Hornady SP Winchester W-760 Subscribe 2847
Remarks: max load; COL: 2.855"; 61,800 psi
195 Hornady SP Hodgdon H-380 Subscribe 2668
Remarks: start load; COL: 2.855"; 54,800 psi
195 Hornady SP Hodgdon H-380 Subscribe 2796
Remarks: max load; COL: 2.855"; 63,300 psi
195 Hornady SP Hodgdon Varget Subscribe 2661
Remarks: start load; COL: 2.855"; 55,500 psi
195 Hornady SP Hodgdon Varget Subscribe 2782
Remarks: max load; COL: 2.855"; 62,800 psi
195 Hornady SP IMR IMR-4320 Subscribe 2654
Remarks: start load; COL: 2.855"; 52,800 psi
195 Hornady SP IMR IMR-4320 Subscribe 2795
Remarks: max load; COL: 2.855"; 62,200 psi
195 Hornady SP IMR IMR-4064 Subscribe 2658
Remarks: start load; COL: 2.855"; 54,700 psi
195 Hornady SP IMR IMR-4064 Subscribe 2789
Remarks: max load; COL: 2.855"; 63,100 psi
195 Hornady SP Hodgdon BL-C(2) Subscribe 2707
Remarks: start load; COL: 2.855"; 55,900 psi
195 Hornady SP Hodgdon BL-C(2) Subscribe 2840
Remarks: max load; COL: 2.855"; 63,700 psi
195 Hornady SP IMR IMR-4895 Subscribe 2623
Remarks: start load; COL: 2.855"; 53,700 psi
195 Hornady SP IMR IMR-4895 Subscribe 2768
Remarks: max load; COL: 2.855"; 61,100 psi
195 Hornady SP Hodgdon H-4895 Subscribe 2648
Remarks: start load; COL: 2.855"; 55,000 psi
195 Hornady SP Hodgdon H-4895 Subscribe 2763
Remarks: max load; COL: 2.855"; 62,500 psi
195 Hornady SP IMR IMR-8208 XBR Subscribe 2617
Remarks: start load; COL: 2.855"; 55,900 psi
195 Hornady SP IMR IMR-8208 XBR Subscribe 2728
Remarks: max load; COL: 2.855"; 62,600 psi
200 Barnes XLC IMR IMR-7828 Subscribe 2614
Remarks: start load; COL: 2.860"; 52,600 psi
200 Barnes XLC IMR IMR-7828 Subscribe 2784
Remarks: max load; compressed; COL: 2.860"; 61,600 psi; reduce by 4%
200 Barnes XLC IMR IMR-4831 Subscribe 2614
Remarks: start load; COL: 2.860"; 48,300 psi
200 Barnes XLC IMR IMR-4831 Subscribe 2788
Remarks: max load; compressed; COL: 2.860"; 58,200 psi
200 Barnes XLC Hodgdon H-4350 Subscribe 2689
Remarks: start load; COL: 2.860"; 52,500 psi
200 Barnes XLC Hodgdon H-4350 Subscribe 2843
Remarks: max load; COL: 2.860"; 62,900 psi
200 Barnes XLC Hodgdon H-414 Subscribe 2686
Remarks: start load; COL: 2.860"; 54,600 psi
200 Barnes XLC Hodgdon H-414 Subscribe 2827
Remarks: max load; COL: 2.860"; 63,400 psi
200 Barnes XLC IMR IMR-4350 Subscribe 2650
Remarks: start load; COL: 2.860"; 51,400 psi
200 Barnes XLC IMR IMR-4350 Subscribe 2818
Remarks: max load; compressed; COL: 2.860"; 62,100 psi
200 Barnes XLC Winchester W-760 Subscribe 2686
Remarks: start load; COL: 2.860"; 54,600 psi
200 Barnes XLC Winchester W-760 Subscribe 2827
Remarks: max load; COL: 2.860"; 63,400 psi
200 Barnes XLC Hodgdon H-380 Subscribe 2629
Remarks: start load; COL: 2.860"; 50,700 psi
200 Barnes XLC Hodgdon H-380 Subscribe 2777
Remarks: max load; COL: 2.860"; 60,000 psi
200 Barnes XLC Hodgdon Varget Subscribe 2642
Remarks: start load; COL: 2.860"; 55,100 psi
200 Barnes XLC Hodgdon Varget Subscribe 2762
Remarks: max load; COL: 2.860"; 62,300 psi
200 Barnes XLC IMR IMR-4320 Subscribe 2590
Remarks: start load; COL: 2.860"; 51,000 psi
200 Barnes XLC IMR IMR-4320 Subscribe 2771
Remarks: max load; COL: 2.860"; 62,700 psi
200 Barnes XLC IMR IMR-4064 Subscribe 2592
Remarks: start load; COL: 2.860"; 51,100 psi
200 Barnes XLC IMR IMR-4064 Subscribe 2759
Remarks: max load; COL: 2.860"; 62,500 psi
200 Barnes XLC Hodgdon BL-C(2) Subscribe 2668
Remarks: start load; COL: 2.860"; 54,700 psi
200 Barnes XLC Hodgdon BL-C(2) Subscribe 2799
Remarks: max load; COL: 2.860"; 63,600 psi
200 Barnes XLC IMR IMR-4895 Subscribe 2596
Remarks: start load; COL: 2.860"; 51,500 psi
200 Barnes XLC IMR IMR-4895 Subscribe 2759
Remarks: max load; COL: 2.860"; 61,400 psi
200 Barnes XLC Hodgdon H-4895 Subscribe 2662
Remarks: start load; COL: 2.860"; 58,400 psi
200 Barnes XLC Hodgdon H-4895 Subscribe 2739
Remarks: max load; COL: 2.860"; 62,200 psi
200 Barnes TSX Hodgdon Hybrid 100V Subscribe 2472
Remarks: start load; COL: 2.820"; 45,300 psi
200 Barnes TSX Hodgdon Hybrid 100V Subscribe 2669
Remarks: max load; compressed; COL: 2.820"; 53,800 psi
220 Swift SP IMR IMR-7828 Subscribe 2469
Remarks: start load; COL: 2.845"; 52,200 psi
220 Swift SP IMR IMR-7828 Subscribe 2643
Remarks: max load; compressed; COL: 2.845"; 61,500 psi; reduce by 4%
220 Swift SP Hodgdon H-4831 Subscribe 2491
Remarks: start load; COL: 2.845"; 52,200 psi
220 Swift SP Hodgdon H-4831 Subscribe 2638
Remarks: max load; compressed; COL: 2.845"; 61,300 psi
220 Swift SP Hodgdon Hybrid 100V Subscribe 2446
Remarks: start load; COL: 2.845"; 49,400 psi
220 Swift SP Hodgdon Hybrid 100V Subscribe 2644
Remarks: max load; compressed; COL: 2.845"; 60,000 psi
220 Swift SP IMR IMR-4831 Subscribe 2549
Remarks: start load; COL: 2.845"; 43,300 psi
220 Swift SP IMR IMR-4831 Subscribe 2706
Remarks: max load; compressed; COL: 2.845"; 54,900 psi
220 Swift SP Hodgdon H-4350 Subscribe 2518
Remarks: start load; COL: 2.845"; 52,700 psi
220 Swift SP Hodgdon H-4350 Subscribe 2649
Remarks: max load; COL: 2.845"; 62,400 psi
220 Swift SP Hodgdon H-414 Subscribe 2557
Remarks: start load; COL: 2.845"; 57,100 psi
220 Swift SP Hodgdon H-414 Subscribe 2669
Remarks: max load; COL: 2.845"; 63,200 psi
220 Swift SP IMR IMR-4350 Subscribe 2467
Remarks: start load; COL: 2.845"; 50,400 psi
220 Swift SP IMR IMR-4350 Subscribe 2647
Remarks: max load; compressed; COL: 2.845"; 60,600 psi
220 Swift SP Winchester W-760 Subscribe 2557
Remarks: start load; COL: 2.845"; 57,100 psi
220 Swift SP Winchester W-760 Subscribe 2669
Remarks: max load; COL: 2.845"; 63,200 psi
220 Swift SP Hodgdon H-380 Subscribe 2468
Remarks: start load; COL: 2.845"; 52,100 psi
220 Swift SP Hodgdon H-380 Subscribe 2627
Remarks: max load; COL: 2.845"; 63,600 psi
220 Swift SP Hodgdon Varget Subscribe 2448
Remarks: start load; COL: 2.845"; 55,800 psi
220 Swift SP Hodgdon Varget Subscribe 2569
Remarks: max load; COL: 2.845"; 62,400 psi
220 Swift SP IMR IMR-4320 Subscribe 2469
Remarks: start load; COL: 2.845"; 56,500 psi
220 Swift SP IMR IMR-4320 Subscribe 2564
Remarks: max load; COL: 2.845"; 61,900 psi
220 Swift SP IMR IMR-4064 Subscribe 2458
Remarks: start load; COL: 2.845"; 54,900 psi
220 Swift SP IMR IMR-4064 Subscribe 2585
Remarks: max load; COL: 2.845"; 63,000 psi
220 Swift SP Hodgdon BL-C(2) Subscribe 2505
Remarks: start load; COL: 2.845"; 56,600 psi
220 Swift SP Hodgdon BL-C(2) Subscribe 2622
Remarks: max load; COL: 2.845"; 62,100 psi
220 Swift SP IMR IMR-4895 Subscribe 2446
Remarks: start load; COL: 2.845"; 52,700 psi
220 Swift SP IMR IMR-4895 Subscribe 2578
Remarks: max load; COL: 2.845"; 61,700 psi
220 Swift SP Hodgdon H-4895 Subscribe 2438
Remarks: start load; COL: 2.845"; 54,800 psi
220 Swift SP Hodgdon H-4895 Subscribe 2556
Remarks: max load; COL: 2.845"; 63,100 psi