Wt. Bullet Powder Manufacturer Powder Charge Velocity (FPS)
100 Jacketed Hodgdon H-414 Subscribe 3086
Remarks: start load; min OAL: 2.900
100 Jacketed Hodgdon H-414 Subscribe 3299
Remarks: NEVER EXCEED; min OAL: 2.900; 51,443 psi
100 Jacketed Hodgdon Varget Subscribe 3069
Remarks: start load; min OAL: 2.900
100 Jacketed Hodgdon Varget Subscribe 3250
Remarks: NEVER EXCEED; min OAL: 2.900; 50,557 psi
100 Jacketed Hodgdon H-380 Subscribe 3077
Remarks: start load; min OAL: 2.900
100 Jacketed Hodgdon H-380 Subscribe 3228
Remarks: NEVER EXCEED; min OAL: 2.900; 50,446 psi
100 Jacketed Hodgdon H-4895 Subscribe 3088
Remarks: start load; min OAL: 2.900
100 Jacketed Hodgdon H-4895 Subscribe 3208
Remarks: NEVER EXCEED; min OAL: 2.900; 50,335 psi
100 Jacketed Hodgdon BL-C(2) Subscribe 3056
Remarks: start load; min OAL: 2.900
100 Jacketed Hodgdon BL-C(2) Subscribe 3205
Remarks: NEVER EXCEED; min OAL: 2.900; 50,889 psi
100 Jacketed Hodgdon H-4350 Subscribe 2989
Remarks: start load; compressed charge; min OAL: 2.900
100 Jacketed Hodgdon H-4350 Subscribe 3166
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.900; 45,678 psi
100 Jacketed Hodgdon H-450 Subscribe 2660
Remarks: start load; min OAL: 2.940
100 Jacketed Hodgdon H-450 Subscribe 2940
Remarks: NEVER EXCEED; min OAL: 2.940; 38,139 psi
100 Jacketed Hodgdon H-4831 Subscribe 2688
Remarks: start load; compressed charge; min OAL: 2.940
100 Jacketed Hodgdon H-4831 Subscribe 2886
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.940; 37,252 psi
110 Jacketed Hodgdon H-414 Subscribe 2901
Remarks: start load; min OAL: 2.980
110 Jacketed Hodgdon H-414 Subscribe 3101
Remarks: NEVER EXCEED; min OAL: 2.980; 48,893 psi
110 Jacketed Hodgdon H-380 Subscribe 2914
Remarks: start load; min OAL: 2.980
110 Jacketed Hodgdon H-380 Subscribe 3085
Remarks: NEVER EXCEED; min OAL: 2.980; 50,224 psi
110 Jacketed Hodgdon Varget Subscribe 2801
Remarks: start load; min OAL: 2.980
110 Jacketed Hodgdon Varget Subscribe 3081
Remarks: NEVER EXCEED; min OAL: 2.980; 51,000 psi
110 Jacketed Hodgdon H-4895 Subscribe 2879
Remarks: start load; min OAL: 2.980
110 Jacketed Hodgdon H-4895 Subscribe 3078
Remarks: NEVER EXCEED; min OAL: 2.980; 49,891 psi
110 Jacketed Hodgdon H-4350 Subscribe 2876
Remarks: start load; compressed charge; min OAL: 2.980
110 Jacketed Hodgdon H-4350 Subscribe 3046
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.980; 46,454 psi
120 Jacketed Alliant RL-19 Subscribe 2601
Remarks: start load; min OAL: 2.965
120 Jacketed Alliant RL-19 Subscribe 3030
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.965; 48,000 psi
120 Jacketed Alliant RL-15 Subscribe 2775
Remarks: start load; min OAL: 2.965
120 Jacketed Alliant RL-15 Subscribe 2995
Remarks: NEVER EXCEED; min OAL: 2.965; 48,900 psi
120 Jacketed Hodgdon Varget Subscribe 2786
Remarks: start load; min OAL: 3.000
120 Jacketed Hodgdon Varget Subscribe 2979
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
120 Jacketed Hodgdon H-4350 Subscribe 2781
Remarks: start load; min OAL: 3.000
120 Jacketed Hodgdon H-4350 Subscribe 2945
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.000 50,778 psi
120 Jacketed Hodgdon H-414 Subscribe 2774
Remarks: start load; min OAL: 3.000
120 Jacketed Hodgdon H-414 Subscribe 2938
Remarks: NEVER EXCEED; min OAL: 3.000; 50,557 psi
120 Jacketed Accurate AAC-2700 Subscribe 2658
Remarks: start load; min OAL: 2.900
120 Jacketed Accurate AAC-2700 Subscribe 2924
Remarks: NEVER EXCEED; min OAL: 2.900; 44,800 cup
120 Jacketed Hodgdon H-450 Subscribe 2757
Remarks: start load; min OAL: 2.940
120 Jacketed Hodgdon H-450 Subscribe 2919
Remarks: NEVER EXCEED; min OAL: 2.940; 47,563 psi
120 Jacketed Accurate AAC-2495 Subscribe 2810
Remarks: start load; min OAL: 2.900
120 Jacketed Accurate AAC-2495 Subscribe 2919
Remarks: NEVER EXCEED; min OAL: 2.900; 42,300 cup
120 Jacketed Alliant RL-12 Subscribe 2682
Remarks: start load; min OAL: 2.965
120 Jacketed Alliant RL-12 Subscribe 2895
Remarks: NEVER EXCEED; min OAL: 2.965; 48,900 psi
120 Jacketed Accurate AAC-4350 Subscribe 2541
Remarks: start load; min OAL: 2.900
120 Jacketed Accurate AAC-4350 Subscribe 2887
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.900; 40,400 cup
120 Jacketed Vihtavuori VV-N150 Subscribe 2644
Remarks: start load; min OAL: 3.012
120 Jacketed Vihtavuori VV-N150 Subscribe 2881
Remarks: NEVER EXCEED; min OAL: 3.012
120 Jacketed Vihtavuori VV-N140 Subscribe 2637
Remarks: start load; min OAL: 3.012
120 Jacketed Vihtavuori VV-N140 Subscribe 2874
Remarks: NEVER EXCEED; min OAL: 3.012
120 Jacketed Hodgdon H-380 Subscribe 2701
Remarks: start load; min OAL: 3.000
120 Jacketed Hodgdon H-380 Subscribe 2860
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
120 Jacketed Hodgdon H-4895 Subscribe 2726
Remarks: start load; min OAL: 3.000
120 Jacketed Hodgdon H-4895 Subscribe 2859
Remarks: NEVER EXCEED; min OAL: 3.000; 50,335 psi
120 Jacketed Accurate AAC-4064 Subscribe 2498
Remarks: start load; min OAL: 2.900
120 Jacketed Accurate AAC-4064 Subscribe 2838
Remarks: NEVER EXCEED; min OAL: 2.900; 44,400 cup
120 Jacketed Vihtavuori VV-N135 Subscribe 2546
Remarks: start load; min OAL: 3.012
120 Jacketed Vihtavuori VV-N135 Subscribe 2825
Remarks: NEVER EXCEED; min OAL: 3.012
120 Jacketed Hodgdon H-4831 Subscribe 2648
Remarks: start load; min OAL: 3.000
120 Jacketed Hodgdon H-4831 Subscribe 2777
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.000 45,235 psi
120 Jacketed Accurate AAC-3100 Subscribe 2263
Remarks: start load; min OAL: 2.900
120 Jacketed Accurate AAC-3100 Subscribe 2572
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.900; 34,000 cup
125 Jacketed Winchester W-760 Subscribe 2699
Remarks: start load; min OAL: 2.940
125 Jacketed Winchester W-760 Subscribe 2885
Remarks: NEVER EXCEED; min OAL: 2.940; 43,500 cup
130 Jacketed Hodgdon H-4350 Subscribe 2689
Remarks: start load; min OAL: 2.800
130 Jacketed Hodgdon H-4350 Subscribe 2848
Remarks: NEVER EXCEED; min OAL: 2.800; 51,000 psi
130 Jacketed Hodgdon Varget Subscribe 2619
Remarks: start load; min OAL: 2.800
130 Jacketed Hodgdon Varget Subscribe 2800
Remarks: NEVER EXCEED; min OAL: 2.800; 50,667 psi
130 Jacketed Hodgdon H-380 Subscribe 2565
Remarks: start load; min OAL: 2.800
130 Jacketed Hodgdon H-380 Subscribe 2769
Remarks: NEVER EXCEED; min OAL: 2.800; 51,000 psi
130 Jacketed Hodgdon H-4831 Subscribe 2646
Remarks: start load; min OAL: 2.940
130 Jacketed Hodgdon H-4831 Subscribe 2763
Remarks: NEVER EXCEED; compressed charge; min OAL: 2.940; 48,783 psi
130 Jacketed IMR IMR-4831 Subscribe 2452
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-4831 Subscribe 2750
Remarks: NEVER EXCEED; min OAL: 2.965; 46,000 cup
130 Jacketed IMR IMR-4350 Subscribe 2440
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-4350 Subscribe 2710
Remarks: NEVER EXCEED; min OAL: 2.965; 45,500 cup
130 Jacketed Hodgdon H-4895 Subscribe 2530
Remarks: start load; min OAL: 2.800
130 Jacketed Hodgdon H-4895 Subscribe 2704
Remarks: NEVER EXCEED; min OAL: 2.800; 51,000 psi
130 Jacketed IMR IMR-4064 Subscribe 2432
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-4064 Subscribe 2675
Remarks: NEVER EXCEED; min OAL: 2.965; 44,900 cup
130 Jacketed IMR IMR-3031 Subscribe 2377
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-3031 Subscribe 2640
Remarks: NEVER EXCEED; min OAL: 2.965; 45,500 cup
130 Jacketed IMR IMR-4895 Subscribe 2287
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-4895 Subscribe 2540
Remarks: NEVER EXCEED; min OAL: 2.965; 45,300 cup
130 Jacketed IMR IMR-4198 Subscribe 2150
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-4198 Subscribe 2365
Remarks: NEVER EXCEED; min OAL: 2.965; 45,100 cup
130 Jacketed IMR IMR-4227 Subscribe 1909
Remarks: start load; min OAL: 2.965
130 Jacketed IMR IMR-4227 Subscribe 2080
Remarks: NEVER EXCEED; min OAL: 2.965; 44,300 cup
130 Jacketed IMR SR-4759 Subscribe 1832
Remarks: start load; min OAL: 2.965
130 Jacketed IMR SR-4759 Subscribe 2055
Remarks: NEVER EXCEED; min OAL: 2.965; 46,000 cup
139 Jacketed Alliant RL-19 Subscribe 2627
Remarks: start load; min OAL: 3.015
139 Jacketed Alliant RL-19 Subscribe 2835
Remarks: NEVER EXCEED; min OAL: 3.015; 49,000 psi
139 Jacketed Alliant RL-22 Subscribe 2737
Remarks: start load; min OAL: 3.015
139 Jacketed Alliant RL-22 Subscribe 2790
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.015; 45,600 psi
139 Jacketed Alliant RL-15 Subscribe 2526
Remarks: start load; min OAL: 3.015
139 Jacketed Alliant RL-15 Subscribe 2700
Remarks: NEVER EXCEED; min OAL: 3.015; 48,400 psi
139 Jacketed Alliant RL-12 Subscribe 2464
Remarks: start load; min OAL: 3.015
139 Jacketed Alliant RL-12 Subscribe 2660
Remarks: NEVER EXCEED; min OAL: 3.015; 48,800 psi
140 Jacketed Accurate AAC-4350 Subscribe 2628
Remarks: start load; min OAL: 3.025
140 Jacketed Accurate AAC-4350 Subscribe 2836
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.025; 43,900 cup
140 Jacketed Accurate AAC-2495 Subscribe 2567
Remarks: start load; min OAL: 3.025
140 Jacketed Accurate AAC-2495 Subscribe 2745
Remarks: NEVER EXCEED; min OAL: 3.025; 43,400 cup
140 Jacketed Accurate AAC-2700 Subscribe 2614
Remarks: start load; min OAL: 3.025
140 Jacketed Accurate AAC-2700 Subscribe 2742
Remarks: NEVER EXCEED; min OAL: 3.025; 42,800 cup
140 Jacketed Hodgdon H-4831 Subscribe 2592
Remarks: start load; min OAL: 3.000
140 Jacketed Hodgdon H-4831 Subscribe 2719
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
140 Jacketed Hodgdon H-414 Subscribe 2563
Remarks: start load; min OAL: 3.000
140 Jacketed Hodgdon H-414 Subscribe 2715
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
140 Jacketed Accurate AAC-4064 Subscribe 2361
Remarks: start load; min OAL: 3.025
140 Jacketed Accurate AAC-4064 Subscribe 2683
Remarks: NEVER EXCEED; min OAL: 3.025; 45,200 cup
140 Jacketed Hodgdon H-4350 Subscribe 2485
Remarks: start load; min OAL: 3.000
140 Jacketed Hodgdon H-4350 Subscribe 2682
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
140 Jacketed Hodgdon H-380 Subscribe 2445
Remarks: start load; min OAL: 3.000
140 Jacketed Hodgdon H-380 Subscribe 2614
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
140 Jacketed Vihtavuori VV-N150 Subscribe 2384
Remarks: start load; min OAL: 3.051
140 Jacketed Vihtavuori VV-N150 Subscribe 2598
Remarks: NEVER EXCEED; min OAL: 3.051
140 Jacketed Vihtavuori VV-N140 Subscribe 2336
Remarks: start load; min OAL: 3.051
140 Jacketed Vihtavuori VV-N140 Subscribe 2569
Remarks: NEVER EXCEED; min OAL: 3.051
140 Jacketed Accurate AAC-3100 Subscribe 2254
Remarks: start load; min OAL: 3.025
140 Jacketed Accurate AAC-3100 Subscribe 2561
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.025; 34,200 cup
140 Jacketed Hodgdon H-4895 Subscribe 2366
Remarks: start load; min OAL: 3.000
140 Jacketed Hodgdon H-4895 Subscribe 2530
Remarks: NEVER EXCEED; min OAL: 3.000; 50,778 psi
140 Jacketed Hodgdon Varget Subscribe 2353
Remarks: start load; min OAL: 3.000
140 Jacketed Hodgdon Varget Subscribe 2516
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
145 Jacketed Vectan TU5000 Subscribe 2434
Remarks: start load; min OAL: 3.060
145 Jacketed Vectan TU5000 Subscribe 2723
Remarks: NEVER EXCEED; min OAL: 3.060; 42,816 cip
145 Jacketed Alliant RL-22 Subscribe 2520
Remarks: start load; min OAL: 3.040
145 Jacketed Alliant RL-22 Subscribe 2720
Remarks: NEVER EXCEED; min OAL: 3.040; 49,000 psi
145 Jacketed Alliant RL-19 Subscribe 2483
Remarks: start load; min OAL: 3.040
145 Jacketed Alliant RL-19 Subscribe 2680
Remarks: NEVER EXCEED; min OAL: 3.040; 48,800 psi
145 Jacketed IMR IMR-4350 Subscribe 2363
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4350 Subscribe 2650
Remarks: NEVER EXCEED; min OAL: 3.065; 46,000 cup
145 Jacketed IMR IMR-4831 Subscribe 2341
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4831 Subscribe 2625
Remarks: NEVER EXCEED; min OAL: 3.065; 46,000 cup
145 Jacketed IMR IMR-4064 Subscribe 2301
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4064 Subscribe 2555
Remarks: NEVER EXCEED; min OAL: 3.065; 45,300 cup
145 Jacketed Alliant RL-15 Subscribe 2385
Remarks: start load; min OAL: 3.040
145 Jacketed Alliant RL-15 Subscribe 2550
Remarks: NEVER EXCEED; min OAL: 3.040; 48,500 psi
145 Jacketed IMR IMR-3031 Subscribe 2256
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-3031 Subscribe 2530
Remarks: NEVER EXCEED; min OAL: 3.065; 46,000 cup
145 Jacketed Alliant RL-12 Subscribe 2335
Remarks: start load; min OAL: 3.040
145 Jacketed Alliant RL-12 Subscribe 2520
Remarks: NEVER EXCEED; min OAL: 3.040; 48,800 psi
145 Jacketed IMR IMR-4895 Subscribe 2207
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4895 Subscribe 2475
Remarks: NEVER EXCEED; min OAL: 3.065; 46,000 cup
145 Jacketed IMR IMR-4320 Subscribe 2150
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4320 Subscribe 2365
Remarks: NEVER EXCEED; min OAL: 3.065; 45,100 cup
145 Jacketed IMR IMR-4198 Subscribe 2016
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4198 Subscribe 2260
Remarks: NEVER EXCEED; min OAL: 3.065; 45,800 cup
145 Jacketed IMR IMR-4227 Subscribe 1689
Remarks: start load; min OAL: 3.065
145 Jacketed IMR IMR-4227 Subscribe 1840
Remarks: NEVER EXCEED; min OAL: 3.065; 44,400 cup
145 Jacketed IMR SR-4759 Subscribe 1669
Remarks: start load; min OAL: 3.065
145 Jacketed IMR SR-4759 Subscribe 1835
Remarks: NEVER EXCEED; min OAL: 3.065; 45,100 cup
145 Lead Accurate AAC-5744 Subscribe 1661
Remarks: start load; min OAL: 2.955
145 Lead Accurate AAC-5744 Subscribe 2238
Remarks: NEVER EXCEED; min OAL: 2.955; 33,300 cup
150 Jacketed Accurate AAC-4350 Subscribe 2522
Remarks: start load; min OAL: 3.060
150 Jacketed Accurate AAC-4350 Subscribe 2722
Remarks: NEVER EXCEED; min OAL: 3.060; 44,000 cup
150 Jacketed Winchester W-760 Subscribe 2488
Remarks: start load; min OAL: 2.940
150 Jacketed Winchester W-760 Subscribe 2660
Remarks: NEVER EXCEED; min OAL: 2.940; 43,500 cup
150 Jacketed Accurate AAC-2700 Subscribe 2480
Remarks: start load; min OAL: 3.060
150 Jacketed Accurate AAC-2700 Subscribe 2626
Remarks: NEVER EXCEED; min OAL: 3.060; 43,200 cup
150 Jacketed Accurate AAC-3100 Subscribe 2271
Remarks: start load; min OAL: 3.060
150 Jacketed Accurate AAC-3100 Subscribe 2581
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.060; 38,200 cup
150 Jacketed Accurate AAC-2495 Subscribe 2366
Remarks: start load; min OAL: 3.060
150 Jacketed Accurate AAC-2495 Subscribe 2578
Remarks: NEVER EXCEED; min OAL: 3.060; 44,400 cup
150 Jacketed Hodgdon H-4831 Subscribe 2401
Remarks: start load; min OAL: 3.000
150 Jacketed Hodgdon H-4831 Subscribe 2542
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
150 Jacketed Hodgdon H-414 Subscribe 2391
Remarks: start load; min OAL: 3.000
150 Jacketed Hodgdon H-414 Subscribe 2532
Remarks: NEVER EXCEED; min OAL: 3.000; 50,335 psi
150 Jacketed Accurate AAC-4064 Subscribe 2216
Remarks: start load; min OAL: 3.060
150 Jacketed Accurate AAC-4064 Subscribe 2519
Remarks: NEVER EXCEED; min OAL: 3.060; 42,200 cup
150 Jacketed Hodgdon H-4350 Subscribe 2350
Remarks: start load; min OAL: 3.000
150 Jacketed Hodgdon H-4350 Subscribe 2513
Remarks: NEVER EXCEED; min OAL: 3.000; 50,446 psi
150 Jacketed Hodgdon H-380 Subscribe 2297
Remarks: start load; min OAL: 3.000
150 Jacketed Hodgdon H-380 Subscribe 2455
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
150 Jacketed Hodgdon H-4895 Subscribe 2250
Remarks: start load; min OAL: 3.000
150 Jacketed Hodgdon H-4895 Subscribe 2383
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
150 Jacketed Hodgdon Varget Subscribe 2240
Remarks: start load; min OAL: 3.000
150 Jacketed Hodgdon Varget Subscribe 2372
Remarks: NEVER EXCEED; min OAL: 3.000; 50,557 psi
160 Jacketed Alliant RL-22 Subscribe 2516
Remarks: start load; min OAL: 3.040
160 Jacketed Alliant RL-22 Subscribe 2690
Remarks: NEVER EXCEED; min OAL: 3.040; 48,300 psi
160 Jacketed Alliant RL-19 Subscribe 2640
Remarks: start load; min OAL: 3.040
160 Jacketed Alliant RL-19 Subscribe 2665
Remarks: NEVER EXCEED; min OAL: 3.040; 45,500 psi
160 Jacketed Accurate AAC-4350 Subscribe 2384
Remarks: start load; min OAL: 3.020
160 Jacketed Accurate AAC-4350 Subscribe 2623
Remarks: NEVER EXCEED; min OAL: 3.020; 45,100 cup
160 Jacketed Accurate AAC-3100 Subscribe 2238
Remarks: start load; min OAL: 3.020
160 Jacketed Accurate AAC-3100 Subscribe 2543
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.020; 39,000 cup
160 Jacketed Vectan TU5000 Subscribe 2343
Remarks: start load; min OAL: 3.060
160 Jacketed Vectan TU5000 Subscribe 2543
Remarks: NEVER EXCEED; min OAL: 3.060; 41,364 cip
160 Jacketed IMR IMR-4831 Subscribe 2287
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4831 Subscribe 2540
Remarks: NEVER EXCEED; min OAL: 3.065; 45,600 cup
160 Jacketed Vihtavuori VV-N160 Subscribe 2330
Remarks: start load; min OAL: 3.051
160 Jacketed Vihtavuori VV-N160 Subscribe 2539
Remarks: NEVER EXCEED; min OAL: 3.051
160 Jacketed IMR IMR-4350 Subscribe 2238
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4350 Subscribe 2510
Remarks: NEVER EXCEED; min OAL: 3.065; 45,800 cup
160 Jacketed Vectan SP7 Subscribe 2365
Remarks: start load; min OAL: 3.060
160 Jacketed Vectan SP7 Subscribe 2497
Remarks: NEVER EXCEED; min OAL: 3.060; 45,036 cip
160 Jacketed IMR IMR-4064 Subscribe 2212
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4064 Subscribe 2480
Remarks: NEVER EXCEED; min OAL: 3.065; 46,000 cup
160 Jacketed IMR IMR-3031 Subscribe 2167
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-3031 Subscribe 2430
Remarks: NEVER EXCEED; min OAL: 3.065; 45,800 cup
160 Jacketed Accurate AAC-2495 Subscribe 2158
Remarks: start load; min OAL: 3.020
160 Jacketed Accurate AAC-2495 Subscribe 2420
Remarks: NEVER EXCEED; min OAL: 3.020; 46,000 cup
160 Jacketed Hodgdon H-4831 Subscribe 2258
Remarks: start load; min OAL: 3.000
160 Jacketed Hodgdon H-4831 Subscribe 2415
Remarks: NEVER EXCEED; min OAL: 3.000; 50,667 psi
160 Jacketed Vihtavuori VV-N150 Subscribe 2216
Remarks: start load; min OAL: 3.051
160 Jacketed Vihtavuori VV-N150 Subscribe 2415
Remarks: NEVER EXCEED; min OAL: 3.051
160 Jacketed Accurate AAC-4064 Subscribe 2117
Remarks: start load; min OAL: 3.020
160 Jacketed Accurate AAC-4064 Subscribe 2406
Remarks: NEVER EXCEED; min OAL: 3.020; 43,600 cup
160 Jacketed Hodgdon H-414 Subscribe 2271
Remarks: start load; min OAL: 3.000
160 Jacketed Hodgdon H-414 Subscribe 2405
Remarks: NEVER EXCEED; min OAL: 3.000; 50,335 psi
160 Jacketed Accurate AAC-2700 Subscribe 2255
Remarks: start load; min OAL: 3.020
160 Jacketed Accurate AAC-2700 Subscribe 2399
Remarks: NEVER EXCEED; min OAL: 3.020; 39,700 cup
160 Jacketed Hodgdon H-4350 Subscribe 2265
Remarks: start load; min OAL: 3.000
160 Jacketed Hodgdon H-4350 Subscribe 2399
Remarks: NEVER EXCEED; min OAL: 3.000; 50,335 psi
160 Jacketed Winchester WMR Subscribe 2194
Remarks: start load; min OAL: 3.060
160 Jacketed Winchester WMR Subscribe 2345
Remarks: NEVER EXCEED; min OAL: 3.060; 48,500 psi
160 Jacketed IMR IMR-4895 Subscribe 2074
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4895 Subscribe 2325
Remarks: NEVER EXCEED; min OAL: 3.065; 45,800 cup
160 Jacketed Hodgdon H-380 Subscribe 2171
Remarks: start load; min OAL: 3.000
160 Jacketed Hodgdon H-380 Subscribe 2299
Remarks: NEVER EXCEED; min OAL: 3.000; 51,000 psi
160 Jacketed IMR IMR-4320 Subscribe 2086
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4320 Subscribe 2295
Remarks: NEVER EXCEED; min OAL: 3.065; 45,200 cup
160 Jacketed Hodgdon Varget Subscribe 2136
Remarks: start load; min OAL: 3.000
160 Jacketed Hodgdon Varget Subscribe 2261
Remarks: NEVER EXCEED; min OAL: 3.000; 50,889 psi
160 Jacketed Hodgdon H-4895 Subscribe 2161
Remarks: start load; min OAL: 3.000
160 Jacketed Hodgdon H-4895 Subscribe 2245
Remarks: NEVER EXCEED; min OAL: 3.000; 49,559 psi
160 Jacketed IMR IMR-4198 Subscribe 1940
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4198 Subscribe 2135
Remarks: NEVER EXCEED; min OAL: 3.065; 44,900 cup
160 Jacketed IMR IMR-4227 Subscribe 1686
Remarks: start load; min OAL: 3.065
160 Jacketed IMR IMR-4227 Subscribe 1890
Remarks: NEVER EXCEED; min OAL: 3.065; 46,000 cup
160 Jacketed IMR SR-4759 Subscribe 1671
Remarks: start load; min OAL: 3.065
160 Jacketed IMR SR-4759 Subscribe 1855
Remarks: NEVER EXCEED; min OAL: 3.065; 45,700 cup
168 Jacketed Hodgdon H-1000 Subscribe 2346
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon H-1000 Subscribe 2485
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.000; 51,000 psi
168 Jacketed Hodgdon Varget Subscribe 2227
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon Varget Subscribe 2404
Remarks: NEVER EXCEED; min OAL: 3.000; 50,446 psi
168 Jacketed Hodgdon H-4831 Subscribe 2238
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon H-4831 Subscribe 2393
Remarks: NEVER EXCEED; min OAL: 3.000; 48,672 psi
168 Jacketed Hodgdon H-414 Subscribe 2245
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon H-414 Subscribe 2378
Remarks: NEVER EXCEED; min OAL: 3.000; 49,891 psi
168 Jacketed Hodgdon H-4350 Subscribe 2245
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon H-4350 Subscribe 2378
Remarks: NEVER EXCEED; min OAL: 3.000; 48,893 psi
168 Jacketed Hodgdon H-380 Subscribe 2145
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon H-380 Subscribe 2272
Remarks: NEVER EXCEED; min OAL: 3.000; 49,337 psi
168 Jacketed Hodgdon H-4895 Subscribe 2128
Remarks: start load; min OAL: 3.000
168 Jacketed Hodgdon H-4895 Subscribe 2211
Remarks: NEVER EXCEED; min OAL: 3.000; 47,230 psi
168 Lead Vectan TU2000 Subscribe 1647
Remarks: start load; min OAL: 3.060
168 Lead Vectan TU2000 Subscribe 1772
Remarks: NEVER EXCEED; min OAL: 3.060; 24,557 cip
175 Jacketed Vectan TU5000 Subscribe 2303
Remarks: start load; min OAL: 3.060
175 Jacketed Vectan TU5000 Subscribe 2543
Remarks: NEVER EXCEED; min OAL: 3.060; 48,200 cip
175 Jacketed Accurate AAC-4350 Subscribe 2279
Remarks: start load; min OAL: 3.040
175 Jacketed Accurate AAC-4350 Subscribe 2507
Remarks: NEVER EXCEED; min OAL: 3.040; 45,000 cup
175 Jacketed Accurate AAC-3100 Subscribe 2149
Remarks: start load; min OAL: 3.040
175 Jacketed Accurate AAC-3100 Subscribe 2442
Remarks: NEVER EXCEED; compressed charge; min OAL: 3.040; 38,400 cup
175 Jacketed Accurate AAC-2700 Subscribe 2203
Remarks: start load; min OAL: 3.040
175 Jacketed Accurate AAC-2700 Subscribe 2401
Remarks: NEVER EXCEED; min OAL: 3.040; 44,500 cup
175 Jacketed Winchester W-760 Subscribe 2202
Remarks: start load; min OAL: 3.060
175 Jacketed Winchester W-760 Subscribe 2400
Remarks: NEVER EXCEED; min OAL: 3.060; 44,500 cup
175 Jacketed Vihtavuori VV-N165 Subscribe 2144
Remarks: start load; min OAL: 3.031
175 Jacketed Vihtavuori VV-N165 Subscribe 2359
Remarks: NEVER EXCEED; min OAL: 3.031
175 Jacketed Accurate AAC-4064 Subscribe 2060
Remarks: start load; min OAL: 3.040
175 Jacketed Accurate AAC-4064 Subscribe 2342
Remarks: NEVER EXCEED; min OAL: 3.040; 45,400 cup
175 Jacketed Vihtavuori VV-N160 Subscribe 2069
Remarks: start load; min OAL: 3.031
175 Jacketed Vihtavuori VV-N160 Subscribe 2320
Remarks: NEVER EXCEED; min OAL: 3.031
175 Jacketed Accurate AAC-2495 Subscribe 2073
Remarks: start load; min OAL: 3.040
175 Jacketed Accurate AAC-2495 Subscribe 2302
Remarks: NEVER EXCEED; min OAL: 3.040; 45,400 cup
175 Jacketed Hodgdon H-1000 Subscribe 2115
Remarks: start load; min OAL: 3.025
175 Jacketed Hodgdon H-1000 Subscribe 2239
Remarks: NEVER EXCEED; min OAL: 3.025; 50,446 psi
175 Jacketed Hodgdon H-4831 Subscribe 2058
Remarks: start load; min OAL: 3.025
175 Jacketed Hodgdon H-4831 Subscribe 2201
Remarks: NEVER EXCEED; min OAL: 3.025; 50,667 psi
175 Jacketed Hodgdon Varget Subscribe 1961
Remarks: start load; min OAL: 3.025
175 Jacketed Hodgdon Varget Subscribe 2178
Remarks: NEVER EXCEED; min OAL: 3.025; 50,446 psi
175 Jacketed Hodgdon H-4350 Subscribe 2058
Remarks: start load; min OAL: 3.025
175 Jacketed Hodgdon H-4350 Subscribe 2159
Remarks: NEVER EXCEED; min OAL: 3.025; 48,117 psi
175 Jacketed Hodgdon H-414 Subscribe 2020
Remarks: start load; min OAL: 3.025
175 Jacketed Hodgdon H-414 Subscribe 2119
Remarks: NEVER EXCEED; min OAL: 3.025; 49,337 psi