MENU

Log into your account

Enter your user name: Enter your password:
The Ultimate Reloading Manual
Wolfe Publishing Group
  • reloading manual
  • alliant reloading data
  • reloading brass
  • shotshell reloading
  • bullet reloading
The Ultimate Reloading Manual

/


.35 Remington (Lee Precision Data)

.35 Remington (Lee Precision Data)
Warning! Notes: CAUTION: With NEVER EXCEED LOADS maintain Minimum Over All Length or longer. Large Rifle primer. (MODERN RELOADING Second Edition - Richard Lee)
Be Alert: Publisher cannot be responsible for errors in published load data.
Wt. Bullet Powder Manufacturer Powder Charge Velocity (FPS)
150 Jacketed IMR IMR-3031 Subscribe 2173
Remarks: start load; compressed charge; min OAL: 2.500
150 Jacketed IMR IMR-3031 Subscribe 2390
Remarks: never exceed; compressed charge; min OAL: 2.500; 34,200 cup
150 Jacketed IMR IMR-4064 Subscribe 2173
Remarks: start load; compressed charge; min OAL: 2.500
150 Jacketed IMR IMR-4064 Subscribe 2390
Remarks: never exceed; compressed charge; min OAL: 2.500; 34,200 cup
150 Jacketed IMR IMR-4895 Subscribe 2107
Remarks: start load; min OAL: 2.500
150 Jacketed IMR IMR-4895 Subscribe 2340
Remarks: never exceed; compressed charge; min OAL: 2.500; 34,600 cup
150 Jacketed IMR IMR-4320 Subscribe 2066
Remarks: start load; min OAL: 2.500
150 Jacketed IMR IMR-4320 Subscribe 2295
Remarks: never exceed; compressed charge; min OAL: 2.500; 34,700 cup
150 Jacketed Alliant RL-7 Subscribe 2290
Remarks: start load; min OAL: 2.485
150 Jacketed Alliant RL-7 Subscribe 2290
Remarks: never exceed; min OAL: 2.485; 30,700 cup
150 Jacketed IMR IMR-4198 Subscribe 1953
Remarks: start load; min OAL: 2.500
150 Jacketed IMR IMR-4198 Subscribe 2190
Remarks: never exceed; min OAL: 2.500; 35,000 cup
150 Jacketed IMR SR-4759 Subscribe 1771
Remarks: start load; min OAL: 2.500
150 Jacketed IMR SR-4759 Subscribe 1985
Remarks: never exceed; min OAL: 2.500; 35,000 cup
150 Jacketed IMR IMR-4350 Subscribe 1985
Remarks: start load; compressed charge; min OAL: 2.500
150 Jacketed IMR IMR-4350 Subscribe 1985
Remarks: never exceed; compressed charge; min OAL: 2.500; 24,100 cup
150 Jacketed IMR IMR-4227 Subscribe 1793
Remarks: start load; min OAL: 2.500
150 Jacketed IMR IMR-4227 Subscribe 1935
Remarks: never exceed; min OAL: 2.500; 33,600 cup
150 Jacketed IMR IMR-4831 Subscribe 1850
Remarks: start load; compressed charge; min OAL: 2.500
150 Jacketed IMR IMR-4831 Subscribe 1850
Remarks: never exceed; compressed charge; min OAL: 2.500; 21,300 cup
158 Lead Alliant RL-7 Subscribe 2200
Remarks: start load; min OAL: 2.485
158 Lead Alliant RL-7 Subscribe 2200
Remarks: never exceed; min OAL: 2.485; 29,800 cup
180 Jacketed Hodgdon H-4895 Subscribe 2029
Remarks: start load; min OAL: 2.470
180 Jacketed Hodgdon H-4895 Subscribe 2232
Remarks: never exceed; min OAL: 2.470; 31,681 psi
180 Jacketed Hodgdon Varget Subscribe 2015
Remarks: start load; min OAL: 2.470
180 Jacketed Hodgdon Varget Subscribe 2196
Remarks: never exceed; compressed charge; min OAL: 2.470; 31,107 psi
180 Jacketed Hodgdon H-4198 Subscribe 1937
Remarks: start load; min OAL: 2.470
180 Jacketed Hodgdon H-4198 Subscribe 2172
Remarks: never exceed; min OAL: 2.470; 31,586 psi
180 Jacketed Hodgdon BL-C(2) Subscribe 1971
Remarks: start load; min OAL: 2.470
180 Jacketed Hodgdon BL-C(2) Subscribe 2147
Remarks: never exceed; min OAL: 2.470; 30,916 psi
180 Jacketed Accurate AAC-2520 Subscribe 1867
Remarks: start load; min OAL: 2.465
180 Jacketed Accurate AAC-2520 Subscribe 2122
Remarks: never exceed; min OAL: 2.465; 27,100 psi
180 Jacketed Accurate AAC-2495 Subscribe 1866
Remarks: start load; min OAL: 2.465
180 Jacketed Accurate AAC-2495 Subscribe 2121
Remarks: never exceed; compressed charge; min OAL: 2.465; 30,000 psi
180 Jacketed Hodgdon H-335 Subscribe 1937
Remarks: start load; min OAL: 2.470
180 Jacketed Hodgdon H-335 Subscribe 2111
Remarks: never exceed; min OAL: 2.470; 32,160 psi
180 Jacketed Hodgdon H-414 Subscribe 1932
Remarks: start load; min OAL: 2.490
180 Jacketed Hodgdon H-414 Subscribe 2106
Remarks: never exceed; compressed charge; min OAL: 2.490
180 Jacketed Hodgdon H-322 Subscribe 1894
Remarks: start load; min OAL: 2.470
180 Jacketed Hodgdon H-322 Subscribe 2104
Remarks: never exceed; min OAL: 2.470; 31,681 psi
180 Jacketed Accurate AAC-2015 Subscribe 1847
Remarks: start load; min OAL: 2.465
180 Jacketed Accurate AAC-2015 Subscribe 2099
Remarks: never exceed; min OAL: 2.465; 27,800 psi
180 Jacketed Accurate AAC-2460 Subscribe 1838
Remarks: start load; min OAL: 2.465
180 Jacketed Accurate AAC-2460 Subscribe 2089
Remarks: never exceed; min OAL: 2.465; 28,300 psi
180 Jacketed Hodgdon H-380 Subscribe 1904
Remarks: start load; min OAL: 2.490
180 Jacketed Hodgdon H-380 Subscribe 2075
Remarks: never exceed; compressed charge; min OAL: 2.490
180 Jacketed Accurate AAC-2230 Subscribe 1814
Remarks: start load; min OAL: 2.465
180 Jacketed Accurate AAC-2230 Subscribe 2061
Remarks: never exceed; min OAL: 2.465; 28,900 psi
180 Jacketed Vectan TU2000 Subscribe 2008
Remarks: start load; min OAL: 2.500
180 Jacketed Vectan TU2000 Subscribe 2047
Remarks: never exceed; min OAL: 2.500; 24,775 cip
180 Jacketed Accurate AAC-5744 Subscribe 1664
Remarks: start load; min OAL: 2.465
180 Jacketed Accurate AAC-5744 Subscribe 1891
Remarks: never exceed; min OAL: 2.465; 32,700 psi
200 Jacketed Vectan SP10 Subscribe 2152
Remarks: start load; min OAL: 2.500
200 Jacketed Vectan SP10 Subscribe 2152
Remarks: never exceed; min OAL: 2.500; 27,126 cip
200 Jacketed Hodgdon Varget Subscribe 1963
Remarks: start load; min OAL: 2.510
200 Jacketed Hodgdon Varget Subscribe 2139
Remarks: never exceed; compressed charge; min OAL: 2.510; 31,873 psi
200 Jacketed Winchester W-748 Subscribe 1993
Remarks: start load; min OAL: 2.490
200 Jacketed Winchester W-748 Subscribe 2130
Remarks: never exceed; min OAL: 2.490; 33,000 cup
200 Jacketed Alliant RL-7 Subscribe 2115
Remarks: start load; min OAL: 2.485
200 Jacketed Alliant RL-7 Subscribe 2115
Remarks: never exceed; min OAL: 2.485; 30,700 cup
200 Jacketed IMR IMR-3031 Subscribe 1900
Remarks: start load; min OAL: 2.500
200 Jacketed IMR IMR-3031 Subscribe 2110
Remarks: never exceed; compressed charge; min OAL: 2.500; 34,700 cup
200 Jacketed Hodgdon H-4895 Subscribe 1936
Remarks: start load; min OAL: 2.510
200 Jacketed Hodgdon H-4895 Subscribe 2110
Remarks: never exceed; min OAL: 2.510; 30,916 psi
200 Jacketed Vectan SP9 Subscribe 2100
Remarks: start load; min OAL: 2.500
200 Jacketed Vectan SP9 Subscribe 2100
Remarks: never exceed; min OAL: 2.500; 24,790 cip
200 Jacketed IMR IMR-4064 Subscribe 1891
Remarks: start load; min OAL: 2.500
200 Jacketed IMR IMR-4064 Subscribe 2080
Remarks: never exceed; compressed charge; min OAL: 2.500; 34,200 cup
200 Jacketed Accurate AAC-2520 Subscribe 1822
Remarks: start load; min OAL: 2.470
200 Jacketed Accurate AAC-2520 Subscribe 2071
Remarks: never exceed; min OAL: 2.470; 27,800 psi
200 Jacketed Accurate AAC-2015 Subscribe 1806
Remarks: start load; min OAL: 2.470
200 Jacketed Accurate AAC-2015 Subscribe 2052
Remarks: never exceed; min OAL: 2.470; 31,000 psi
200 Jacketed Hodgdon H-335 Subscribe 1844
Remarks: start load; min OAL: 2.510
200 Jacketed Hodgdon H-335 Subscribe 2048
Remarks: never exceed; min OAL: 2.510; 31,777 psi
200 Jacketed IMR IMR-4895 Subscribe 1810
Remarks: start load; min OAL: 2.500
200 Jacketed IMR IMR-4895 Subscribe 2030
Remarks: never exceed; min OAL: 2.500; 34,900 cup
200 Jacketed Accurate AAC-2460 Subscribe 1785
Remarks: start load; min OAL: 2.470
200 Jacketed Accurate AAC-2460 Subscribe 2028
Remarks: never exceed; min OAL: 2.470; 27,200 psi
200 Jacketed Accurate AAC-2495 Subscribe 1784
Remarks: start load; min OAL: 2.470
200 Jacketed Accurate AAC-2495 Subscribe 2027
Remarks: never exceed; compressed charge; min OAL: 2.470; 25,500 psi
200 Jacketed IMR IMR-4320 Subscribe 1802
Remarks: start load; min OAL: 2.500
200 Jacketed IMR IMR-4320 Subscribe 2020
Remarks: never exceed; min OAL: 2.500; 35,000 cup
200 Jacketed Hodgdon BL-C(2) Subscribe 1863
Remarks: start load; min OAL: 2.510
200 Jacketed Hodgdon BL-C(2) Subscribe 2011
Remarks: never exceed; min OAL: 2.510; 30,341 psi
200 Jacketed Hodgdon H-4198 Subscribe 1800
Remarks: start load; min OAL: 2.510
200 Jacketed Hodgdon H-4198 Subscribe 1999
Remarks: never exceed; min OAL: 2.510; 30,341 psi
200 Jacketed Hodgdon H-322 Subscribe 1840
Remarks: start load; min OAL: 2.510
200 Jacketed Hodgdon H-322 Subscribe 1987
Remarks: never exceed; min OAL: 2.510; 31,681 psi
200 Jacketed Accurate AAC-2230 Subscribe 1744
Remarks: start load; min OAL: 2.470
200 Jacketed Accurate AAC-2230 Subscribe 1982
Remarks: never exceed; min OAL: 2.470; 30,900 psi
200 Jacketed IMR IMR-4198 Subscribe 1774
Remarks: start load; min OAL: 2.500
200 Jacketed IMR IMR-4198 Subscribe 1915
Remarks: never exceed; min OAL: 2.500; 33,500 cup
200 Jacketed IMR IMR-4350 Subscribe 1915
Remarks: start load; compressed charge; min OAL: 2.500
200 Jacketed IMR IMR-4350 Subscribe 1915
Remarks: never exceed; compressed charge; min OAL: 2.500; 29,200 cup
200 Jacketed IMR IMR-4831 Subscribe 1780
Remarks: start load; compressed charge; min OAL: 2.500
200 Jacketed IMR IMR-4831 Subscribe 1780
Remarks: never exceed; compressed charge; min OAL: 2.500; 25,900 cup
200 Jacketed Accurate AAC-5744 Subscribe 1563
Remarks: start load; min OAL: 2.470
200 Jacketed Accurate AAC-5744 Subscribe 1777
Remarks: never exceed; min OAL: 2.470; 29,800 psi
200 Jacketed IMR SR-4759 Subscribe 1579
Remarks: start load; min OAL: 2.500
200 Jacketed IMR SR-4759 Subscribe 1770
Remarks: never exceed; min OAL: 2.500; 35,000 cup
200 Jacketed IMR IMR-4227 Subscribe 1570
Remarks: start load; min OAL: 2.500
200 Jacketed IMR IMR-4227 Subscribe 1760
Remarks: never exceed; min OAL: 2.500; 35,000 cup
200 Lead Accurate AAC-2520 Subscribe 1834
Remarks: start load; min OAL: 2.410
200 Lead Accurate AAC-2520 Subscribe 2084
Remarks: never exceed; min OAL: 2.410; 30,900 psi
200 Lead Accurate AAC-2495 Subscribe 1769
Remarks: start load; min OAL: 2.410
200 Lead Accurate AAC-2495 Subscribe 2010
Remarks: never exceed; compressed charge; min OAL: 2.410; 24,000 psi
200 Lead Accurate AAC-2460 Subscribe 1726
Remarks: start load; min OAL: 2.410
200 Lead Accurate AAC-2460 Subscribe 1961
Remarks: never exceed; min OAL: 2.410; 30,300 psi
200 Lead Accurate AAC-2015 Subscribe 1705
Remarks: start load; min OAL: 2.410
200 Lead Accurate AAC-2015 Subscribe 1938
Remarks: never exceed; min OAL: 2.410; 30,800 psi
200 Lead Accurate AAC-2230 Subscribe 1680
Remarks: start load; min OAL: 2.410
200 Lead Accurate AAC-2230 Subscribe 1909
Remarks: never exceed; min OAL: 2.410; 29,700 psi
200 Lead Vectan TU2000 Subscribe 1709
Remarks: start load; min OAL: 2.500
200 Lead Vectan TU2000 Subscribe 1781
Remarks: never exceed; min OAL: 2.500; 21,234 cip
200 Lead Accurate AAC-5744 Subscribe 1546
Remarks: start load; min OAL: 2.410
200 Lead Accurate AAC-5744 Subscribe 1757
Remarks: never exceed; min OAL: 2.410; 27,600 psi
220 Jacketed Hodgdon H-4895 Subscribe 1844
Remarks: start load; min OAL: 2.470
220 Jacketed Hodgdon H-4895 Subscribe 2010
Remarks: never exceed; min OAL: 2.470; 32,160 psi
220 Jacketed Hodgdon Varget Subscribe 1799
Remarks: start load; min OAL: 2.470
220 Jacketed Hodgdon Varget Subscribe 1998
Remarks: never exceed; min OAL: 2.470; 31,873 psi
220 Jacketed Hodgdon BL-C(2) Subscribe 1759
Remarks: start load; min OAL: 2.470
220 Jacketed Hodgdon BL-C(2) Subscribe 1917
Remarks: never exceed; min OAL: 2.470; 29,671 psi
220 Jacketed Hodgdon H-380 Subscribe 1723
Remarks: start load; min OAL: 2.490
220 Jacketed Hodgdon H-380 Subscribe 1878
Remarks: never exceed; min OAL: 2.490
220 Jacketed Hodgdon H-322 Subscribe 1684
Remarks: start load; min OAL: 2.470
220 Jacketed Hodgdon H-322 Subscribe 1870
Remarks: never exceed; min OAL: 2.470; 31,203 psi
220 Jacketed Hodgdon H-4198 Subscribe 1697
Remarks: start load; min OAL: 2.470
220 Jacketed Hodgdon H-4198 Subscribe 1867
Remarks: never exceed; min OAL: 2.470; 31,969 psi
220 Jacketed Hodgdon H-414 Subscribe 1708
Remarks: start load; min OAL: 2.490
220 Jacketed Hodgdon H-414 Subscribe 1862
Remarks: never exceed; min OAL: 2.490
220 Jacketed Hodgdon H-335 Subscribe 1656
Remarks: start load; min OAL: 2.470
220 Jacketed Hodgdon H-335 Subscribe 1821
Remarks: never exceed; min OAL: 2.470; 31,969 psi
250 Lead Accurate AAC-2460 Subscribe 1614
Remarks: start load; min OAL: 2.685
250 Lead Accurate AAC-2460 Subscribe 1717
Remarks: never exceed; min OAL: 2.685; 32,200 psi
250 Lead Accurate AAC-2495 Subscribe 1595
Remarks: start load; min OAL: 2.685
250 Lead Accurate AAC-2495 Subscribe 1697
Remarks: never exceed; min OAL: 2.685; 26,100 psi
250 Lead Accurate AAC-2520 Subscribe 1550
Remarks: start load; min OAL: 2.685
250 Lead Accurate AAC-2520 Subscribe 1649
Remarks: never exceed; min OAL: 2.685; 30,700 psi
250 Lead Accurate AAC-2230 Subscribe 1543
Remarks: start load; min OAL: 2.685
250 Lead Accurate AAC-2230 Subscribe 1641
Remarks: never exceed; min OAL: 2.685; 33,500 psi
250 Lead Accurate AAC-2015 Subscribe 1451
Remarks: start load; min OAL: 2.685
250 Lead Accurate AAC-2015 Subscribe 1544
Remarks: never exceed; min OAL: 2.685; 31,800 psi