Wt. Bullet Powder Manufacturer Powder Charge Velocity (FPS)
36 Barnes VG FB IMR IMR-4320 Subscribe 2758
Remarks: start load; COL: 2.200"; 39,700 psi
36 Barnes VG FB IMR IMR-4320 Subscribe 3120
Remarks: max load; compressed; COL: 2.200"; 52,200 psi
36 Barnes VG FB IMR IMR-4895 Subscribe 2725
Remarks: start load; COL: 2.200"; 39,700 psi
36 Barnes VG FB IMR IMR-4895 Subscribe 3014
Remarks: max load; compressed; COL: 2.200"; 50,100 psi
36 Barnes VG FB IMR IMR-8208 XBR Subscribe 2829
Remarks: start load; COL: 2.200"; 44,500 psi
36 Barnes VG FB IMR IMR-8208 XBR Subscribe 3057
Remarks: max load; compressed; COL: 2.200"; 50,600 psi
36 Barnes VG FB IMR IMR-3031 Subscribe 2839
Remarks: start load; COL: 2.200"; 41,600 psi
36 Barnes VG FB IMR IMR-3031 Subscribe 3068
Remarks: max load; compressed; COL: 2.200"; 48,200 psi
36 Barnes VG FB IMR IMR-4198 Subscribe 2995
Remarks: start load; COL: 2.200"; 43,500 psi
36 Barnes VG FB IMR IMR-4198 Subscribe 3247
Remarks: max load; COL: 2.200"; 52,500 psi
40 Nosler BT Hodgdon Varget Subscribe 2609
Remarks: start load; COL: 2.280"; 34,400 cup
40 Nosler BT Hodgdon Varget Subscribe 3069
Remarks: max load; compressed; COL: 2.280"; 47,200 cup
40 Nosler BT IMR IMR-4320 Subscribe 2781
Remarks: start load; COL: 2.280"; 43,500 psi
40 Nosler BT IMR IMR-4320 Subscribe 3049
Remarks: max load; compressed; COL: 2.280"; 48,900 psi
40 Nosler BT Hodgdon BL-C(2) Subscribe 2696
Remarks: start load; COL: 2.280"; 35,400 cup
40 Nosler BT Hodgdon BL-C(2) Subscribe 2910
Remarks: max load; COL: 2.280"; 45,400 cup
40 Nosler BT IMR IMR-4895 Subscribe 2653
Remarks: start load; COL: 2.280"; 35,200 psi
40 Nosler BT IMR IMR-4895 Subscribe 2907
Remarks: max load; compressed; COL: 2.280"; 44,200 psi
40 Nosler BT Hodgdon H-335 Subscribe 2931
Remarks: start load; COL: 2.280"; 34,400 cup
40 Nosler BT Hodgdon H-335 Subscribe 3231
Remarks: max load; COL: 2.280"; 44,600 cup
40 Nosler BT Hodgdon H-4895 Subscribe 2628
Remarks: start load; COL: 2.280"; 32,100 cup
40 Nosler BT Hodgdon H-4895 Subscribe 3060
Remarks: max load; compressed; COL: 2.280"; 44,500 cup
40 Nosler BT IMR IMR-8208 XBR Subscribe 2755
Remarks: start load; COL: 2.280"; 41,500 psi
40 Nosler BT IMR IMR-8208 XBR Subscribe 2985
Remarks: max load; compressed; COL: 2.280"; 50,400 psi
40 Nosler BT IMR IMR-3031 Subscribe 2746
Remarks: start load; COL: 2.280"; 42,600 psi
40 Nosler BT IMR IMR-3031 Subscribe 3066
Remarks: max load; compressed; COL: 2.280"; 46,200 psi
40 Nosler BT Hodgdon Benchmark Subscribe 2900
Remarks: start load; COL: 2.280"; 39,600 cup
40 Nosler BT Hodgdon Benchmark Subscribe 3174
Remarks: max load; COL: 2.280"; 51,000 cup
40 Nosler BT Hodgdon H-322 Subscribe 2783
Remarks: start load; COL: 2.280"; 34,600 cup
40 Nosler BT Hodgdon H-322 Subscribe 3087
Remarks: max load; COL: 2.280"; 48,000 cup
40 Nosler BT IMR IMR-4198 Subscribe 2901
Remarks: start load; COL: 2.280"; 42,500 psi
40 Nosler BT IMR IMR-4198 Subscribe 3129
Remarks: max load; COL: 2.280"; 53,400 psi
40 Nosler BT Hodgdon H-4198 Subscribe 2755
Remarks: start load; COL: 2.280"; 29,400 cup
40 Nosler BT Hodgdon H-4198 Subscribe 3014
Remarks: max load; COL: 2.280"; 49,600 cup
45 Sierra SP Hodgdon Varget Subscribe 2550
Remarks: start load; COL: 2.240"; 30,200 cup
45 Sierra SP Hodgdon Varget Subscribe 3010
Remarks: max load; compressed; COL: 2.240"; 43,700 cup
45 Sierra SP IMR IMR-4320 Subscribe 2601
Remarks: start load; COL: 2.240"; 40,300 psi
45 Sierra SP IMR IMR-4320 Subscribe 2982
Remarks: max load; compressed; COL: 2.240"; 46,300 psi
45 Sierra SP Hodgdon BL-C(2) Subscribe 2644
Remarks: start load; COL: 2.240"; 36,000 cup
45 Sierra SP Hodgdon BL-C(2) Subscribe 2915
Remarks: max load; COL: 2.240"; 48,000 cup
45 Sierra SP Hodgdon H-335 Subscribe 2667
Remarks: start load; COL: 2.240"; 41,500 cup
45 Sierra SP Hodgdon H-335 Subscribe 2877
Remarks: max load; COL: 2.240"; 51,000 cup
45 Sierra SP Hodgdon H-4895 Subscribe 2603
Remarks: start load; COL: 2.240"; 33,800 cup
45 Sierra SP Hodgdon H-4895 Subscribe 3017
Remarks: max load; compressed; COL: 2.240"; 43,400 cup
45 Sierra SP IMR IMR-8208 XBR Subscribe 2617
Remarks: start load; COL: 2.240"; 41,700 psi
45 Sierra SP IMR IMR-8208 XBR Subscribe 3022
Remarks: max load; COL: 2.240"; 52,000 psi
45 Sierra SP IMR IMR-3031 Subscribe 2506
Remarks: start load; COL: 2.240"; 37,700 psi
45 Sierra SP IMR IMR-3031 Subscribe 2980
Remarks: max load; compressed; COL: 2.240"; 45,800 psi
45 Sierra SP Hodgdon Benchmark Subscribe 2815
Remarks: start load; COL: 2.240"; 41,400 cup
45 Sierra SP Hodgdon Benchmark Subscribe 3089
Remarks: max load; COL: 2.240"; 51,100 cup
45 Sierra SP Hodgdon H-322 Subscribe 2635
Remarks: start load; COL: 2.240"; 36,000 cup
45 Sierra SP Hodgdon H-322 Subscribe 2926
Remarks: max load; COL: 2.240"; 47,400 cup
45 Sierra SP IMR IMR-4198 Subscribe 2731
Remarks: start load; COL: 2.240"; 44,600 psi
45 Sierra SP IMR IMR-4198 Subscribe 3005
Remarks: max load; COL: 2.240"; 52,000 psi
45 Sierra SP Hodgdon H-4198 Subscribe 2617
Remarks: start load; COL: 2.240"; 28,800 cup
45 Sierra SP Hodgdon H-4198 Subscribe 2847
Remarks: max load; COL: 2.240"; 49,100 cup
50 Speer SP Hodgdon Varget Subscribe 2842
Remarks: start load; COL: 2.210"; 40,800 cup
50 Speer SP Hodgdon Varget Subscribe 2959
Remarks: max load; compressed; COL: 2.210"; 44,800 cup
50 Speer SP IMR IMR-4320 Subscribe 2461
Remarks: start load; COL: 2.210"; 39,400 psi
50 Speer SP IMR IMR-4320 Subscribe 2852
Remarks: max load; compressed; COL: 2.210"; 48,900 psi
50 Speer SP Hodgdon BL-C(2) Subscribe 2569
Remarks: start load; COL: 2.210"; 34,200 cup
50 Speer SP Hodgdon BL-C(2) Subscribe 2851
Remarks: max load; COL: 2.210"; 47,100 cup
50 Speer SP IMR IMR-4895 Subscribe 2646
Remarks: start load; COL: 2.210"; 43,300 psi
50 Speer SP IMR IMR-4895 Subscribe 2892
Remarks: max load; compressed; COL: 2.210"; 45,200 psi
50 Speer SP Hodgdon H-335 Subscribe 2538
Remarks: start load; COL: 2.210"; 43,000 cup
50 Speer SP Hodgdon H-335 Subscribe 2834
Remarks: max load; COL: 2.210"; 51,700 cup
50 Speer SP Hodgdon H-4895 Subscribe 2658
Remarks: start load; COL: 2.210"; 38,300 cup
50 Speer SP Hodgdon H-4895 Subscribe 3024
Remarks: max load; compressed; COL: 2.210"; 51,300 cup
50 Speer SP IMR IMR-8208 XBR Subscribe 2525
Remarks: start load; COL: 2.210"; 40,500 psi
50 Speer SP IMR IMR-8208 XBR Subscribe 2849
Remarks: max load; COL: 2.210"; 53,300 psi
50 Speer SP IMR IMR-3031 Subscribe 2698
Remarks: start load; COL: 2.210"; 44,600 psi
50 Speer SP IMR IMR-3031 Subscribe 3002
Remarks: max load; compressed; COL: 2.210"; 46,900 psi
50 Speer SP Hodgdon Benchmark Subscribe 2639
Remarks: start load; COL: 2.210"; 38,600 cup
50 Speer SP Hodgdon Benchmark Subscribe 2953
Remarks: max load; COL: 2.210"; 50,400 cup
50 Speer SP Hodgdon H-322 Subscribe 2460
Remarks: start load; COL: 2.210"; 36,500 cup
50 Speer SP Hodgdon H-322 Subscribe 2740
Remarks: max load; COL: 2.210"; 49,300 cup
50 Speer SP IMR IMR-4198 Subscribe 2769
Remarks: start load; COL: 2.210"; 42,800 psi
50 Speer SP IMR IMR-4198 Subscribe 3012
Remarks: max load; COL: 2.210"; 32,400 psi
50 Speer SP Hodgdon H-4198 Subscribe 2429
Remarks: start load; COL: 2.210"; 36,500 cup
50 Speer SP Hodgdon H-4198 Subscribe 2824
Remarks: max load; COL: 2.210"; 45,900 cup
53 Sierra HP Hodgdon Varget Subscribe 2449
Remarks: start load; COL: 2.200"; 38,400 cup
53 Sierra HP Hodgdon Varget Subscribe 2833
Remarks: max load; compressed; COL: 2.200"; 47,900 cup
53 Sierra HP IMR IMR-4320 Subscribe 2365
Remarks: start load; COL: 2.200"; 40,400 psi
53 Sierra HP IMR IMR-4320 Subscribe 2851
Remarks: max load; compressed; COL: 2.200"; 52,300 psi
53 Sierra HP IMR IMR-4064 Subscribe 2483
Remarks: start load; COL: 2.200"; 41,600 psi
53 Sierra HP IMR IMR-4064 Subscribe 2765
Remarks: max load; compressed; COL: 2.200"; 45,600 psi
53 Sierra HP Hodgdon BL-C(2) Subscribe 2562
Remarks: start load; COL: 2.200"; 36,600 cup
53 Sierra HP Hodgdon BL-C(2) Subscribe 2914
Remarks: max load; COL: 2.200"; 47,600 cup
53 Sierra HP IMR IMR-4895 Subscribe 2568
Remarks: start load; COL: 2.200"; 43,900 psi
53 Sierra HP IMR IMR-4895 Subscribe 2856
Remarks: max load; compressed; COL: 2.200"; 52,300 psi
53 Sierra HP Hodgdon H-335 Subscribe 2539
Remarks: start load; COL: 2.200"; 44,100 cup
53 Sierra HP Hodgdon H-335 Subscribe 2880
Remarks: max load; COL: 2.200"; 52,000 cup
53 Sierra HP Hodgdon H-4895 Subscribe 2660
Remarks: start load; COL: 2.200"; 37,400 cup
53 Sierra HP Hodgdon H-4895 Subscribe 2965
Remarks: max load; compressed; COL: 2.200"; 48,600 cup
53 Sierra HP IMR IMR-8208 XBR Subscribe 2382
Remarks: start load; COL: 2.200"; 41,400 psi
53 Sierra HP IMR IMR-8208 XBR Subscribe 2789
Remarks: max load; COL: 2.200"; 53,400 psi
53 Sierra HP IMR IMR-3031 Subscribe 2401
Remarks: start load; COL: 2.200"; 40,700 psi
53 Sierra HP IMR IMR-3031 Subscribe 2869
Remarks: max load; compressed; COL: 2.200"; 53,300 psi
53 Sierra HP Hodgdon Benchmark Subscribe 2652
Remarks: start load; COL: 2.200"; 39,900 cup
53 Sierra HP Hodgdon Benchmark Subscribe 2932
Remarks: max load; COL: 2.200"; 49,800 cup
53 Sierra HP Hodgdon H-322 Subscribe 2527
Remarks: start load; COL: 2.200"; 39,200 cup
53 Sierra HP Hodgdon H-322 Subscribe 2707
Remarks: max load; COL: 2.200"; 48,900 cup
53 Sierra HP IMR IMR-4198 Subscribe 2680
Remarks: start load; COL: 2.200"; 43,800 psi
53 Sierra HP IMR IMR-4198 Subscribe 2886
Remarks: max load; COL: 2.200"; 48,200 psi
53 Sierra HP Hodgdon H-4198 Subscribe 2650
Remarks: start load; COL: 2.200"; 34,200 cup
53 Sierra HP Hodgdon H-4198 Subscribe 2846
Remarks: max load; COL: 2.200"; 46,700 cup
55 Speer SP Hodgdon Varget Subscribe 2697
Remarks: start load; COL: 2.200"; 41,300 cup
55 Speer SP Hodgdon Varget Subscribe 2972
Remarks: max load; compressed; COL: 2.200"; 49,700 cup
55 Speer SP IMR IMR-4320 Subscribe 2254
Remarks: start load; COL: 2.200"; 41,300 psi
55 Speer SP IMR IMR-4320 Subscribe 2652
Remarks: max load; compressed; COL: 2.200"; 50,700 psi
55 Speer SP IMR IMR-4064 Subscribe 2268
Remarks: start load; COL: 2.200"; 40,300 psi
55 Speer SP IMR IMR-4064 Subscribe 2672
Remarks: max load; compressed; COL: 2.200"; 52,600 psi
55 Speer SP Hodgdon BL-C(2) Subscribe 2558
Remarks: start load; COL: 2.200"; 37,200 cup
55 Speer SP Hodgdon BL-C(2) Subscribe 2816
Remarks: max load; COL: 2.200"; 48,500 cup
55 Speer SP IMR IMR-4895 Subscribe 2251
Remarks: start load; COL: 2.200"; 39,500 psi
55 Speer SP IMR IMR-4895 Subscribe 2757
Remarks: max load; compressed; COL: 2.200"; 53,200 psi
55 Speer SP Hodgdon H-335 Subscribe 2463
Remarks: start load; COL: 2.200"; 40,800 cup
55 Speer SP Hodgdon H-335 Subscribe 2799
Remarks: max load; COL: 2.200"; 49,300 cup
55 Speer SP Hodgdon H-4895 Subscribe 2721
Remarks: start load; COL: 2.200"; 39,700 cup
55 Speer SP Hodgdon H-4895 Subscribe 2880
Remarks: max load; COL: 2.200"; 49,000 cup
55 Speer SP IMR IMR-8208 XBR Subscribe 2390
Remarks: start load; COL: 2.200"; 42,100 psi
55 Speer SP IMR IMR-8208 XBR Subscribe 2715
Remarks: max load; COL: 2.200"; 53,100 psi
55 Speer SP IMR IMR-3031 Subscribe 2300
Remarks: start load; COL: 2.200"; 41,100 psi
55 Speer SP IMR IMR-3031 Subscribe 2874
Remarks: max load; compressed; COL: 2.200"; 52,500 psi
55 Speer SP Hodgdon Benchmark Subscribe 2625
Remarks: start load; COL: 2.200"; 42,600 cup
55 Speer SP Hodgdon Benchmark Subscribe 2840
Remarks: max load; COL: 2.200"; 50,000 cup
55 Speer SP Hodgdon H-322 Subscribe 2439
Remarks: start load; COL: 2.200"; 38,600 cup
55 Speer SP Hodgdon H-322 Subscribe 2638
Remarks: max load; COL: 2.200"; 48,900 cup
55 Speer SP IMR IMR-4198 Subscribe 2599
Remarks: start load; COL: 2.200"; 41,600 psi
55 Speer SP IMR IMR-4198 Subscribe 2789
Remarks: max load; COL: 2.200"; 53,600 psi
55 Speer SP Hodgdon H-4198 Subscribe 2400
Remarks: start load; COL: 2.200"; 34,800 cup
55 Speer SP Hodgdon H-4198 Subscribe 2719
Remarks: max load; COL: 2.200"; 47,600 cup
60 Hornady V-Max Hodgdon Varget Subscribe 2544
Remarks: start load; COL: 2.250"; 40,400 cup
60 Hornady V-Max Hodgdon Varget Subscribe 2825
Remarks: max load; compressed; COL: 2.250"; 51,900 cup
60 Hornady V-Max IMR IMR-4320 Subscribe 2309
Remarks: start load; COL: 2.250"; 45,400 psi
60 Hornady V-Max IMR IMR-4320 Subscribe 2529
Remarks: max load; compressed; COL: 2.250"; 52,100 psi
60 Hornady V-Max IMR IMR-4064 Subscribe 2312
Remarks: start load; COL: 2.250"; 42,500 psi
60 Hornady V-Max IMR IMR-4064 Subscribe 2517
Remarks: max load; compressed; COL: 2.250"; 52,600 psi
60 Hornady V-Max Hodgdon BL-C(2) Subscribe 2482
Remarks: start load; COL: 2.250"; 44,900 cup
60 Hornady V-Max Hodgdon BL-C(2) Subscribe 2791
Remarks: max load; COL: 2.250"; 51,900 cup
60 Hornady V-Max IMR IMR-4895 Subscribe 2386
Remarks: start load; COL: 2.250"; 45,000 psi
60 Hornady V-Max IMR IMR-4895 Subscribe 2619
Remarks: max load; COL: 2.250"; 52,700 psi
60 Hornady V-Max Hodgdon H-335 Subscribe 2401
Remarks: start load; COL: 2.250"; 43,700 cup
60 Hornady V-Max Hodgdon H-335 Subscribe 2643
Remarks: max load; COL: 2.250"; 50,600 cup
60 Hornady V-Max Hodgdon H-4895 Subscribe 2514
Remarks: start load; COL: 2.250"; 37,600 cup
60 Hornady V-Max Hodgdon H-4895 Subscribe 2804
Remarks: max load; compressed; COL: 2.250"; 50,100 cup
60 Hornady V-Max IMR IMR-8208 XBR Subscribe 2179
Remarks: start load; COL: 2.250"; 43,500 psi
60 Hornady V-Max IMR IMR-8208 XBR Subscribe 2488
Remarks: max load; COL: 2.250"; 51,700 psi
60 Hornady V-Max IMR IMR-3031 Subscribe 2281
Remarks: start load; COL: 2.250"; 42,500 psi
60 Hornady V-Max IMR IMR-3031 Subscribe 2514
Remarks: max load; COL: 2.250"; 51,700 psi
60 Hornady V-Max Hodgdon Benchmark Subscribe 2515
Remarks: start load; COL: 2.250"; 42,500 cup
60 Hornady V-Max Hodgdon Benchmark Subscribe 2744
Remarks: max load; COL: 2.250"; 49,900 cup
60 Hornady V-Max Hodgdon H-322 Subscribe 2526
Remarks: start load; COL: 2.250"; 40,300 cup
60 Hornady V-Max Hodgdon H-322 Subscribe 2657
Remarks: max load; COL: 2.250"; 49,800 cup
60 Hornady V-Max IMR IMR-4198 Subscribe 2488
Remarks: start load; COL: 2.250"; 42,500 psi
60 Hornady V-Max IMR IMR-4198 Subscribe 2570
Remarks: max load; COL: 2.250"; 52,000 psi
60 Hornady V-Max Hodgdon H-4198 Subscribe 2450
Remarks: start load; COL: 2.250"; 42,500 cup
60 Hornady V-Max Hodgdon H-4198 Subscribe 2647
Remarks: max load; COL: 2.250"; 47,600 cup
63 Sierra SP Hodgdon Varget Subscribe 2566
Remarks: start load; COL: 2.200"; 42,400 cup
63 Sierra SP Hodgdon Varget Subscribe 2809
Remarks: max load; COL: 2.200"; 50,700 cup
63 Sierra SP IMR IMR-4320 Subscribe 2206
Remarks: start load; COL: 2.200"; 42,500 psi
63 Sierra SP IMR IMR-4320 Subscribe 2533
Remarks: max load; COL: 2.200"; 52,900 psi
63 Sierra SP IMR IMR-4064 Subscribe 2203
Remarks: start load; COL: 2.200"; 44,400 psi
63 Sierra SP IMR IMR-4064 Subscribe 2566
Remarks: max load; COL: 2.200"; 52,600 psi
63 Sierra SP Hodgdon BL-C(2) Subscribe 2347
Remarks: start load; COL: 2.200"; 36,600 cup
63 Sierra SP Hodgdon BL-C(2) Subscribe 2630
Remarks: max load; COL: 2.200"; 46,300 cup
63 Sierra SP IMR IMR-4895 Subscribe 2308
Remarks: start load; COL: 2.200"; 42,700 psi
63 Sierra SP IMR IMR-4895 Subscribe 2638
Remarks: max load; COL: 2.200"; 53,500 psi
63 Sierra SP Hodgdon H-335 Subscribe 2390
Remarks: start load; COL: 2.200"; 41,000 cup
63 Sierra SP Hodgdon H-335 Subscribe 2724
Remarks: max load; COL: 2.200"; 50,000 cup
63 Sierra SP Hodgdon H-4895 Subscribe 2434
Remarks: start load; COL: 2.200"; 43,300 cup
63 Sierra SP Hodgdon H-4895 Subscribe 2800
Remarks: max load; COL: 2.200"; 50,000 cup
63 Sierra SP IMR IMR-8208 XBR Subscribe 2158
Remarks: start load; COL: 2.200"; 43,000 psi
63 Sierra SP IMR IMR-8208 XBR Subscribe 2409
Remarks: max load; COL: 2.200"; 52,400 psi
63 Sierra SP IMR IMR-3031 Subscribe 2247
Remarks: start load; COL: 2.200"; 42,900 psi
63 Sierra SP IMR IMR-3031 Subscribe 2674
Remarks: max load; COL: 2.200"; 53,000 psi
63 Sierra SP Hodgdon Benchmark Subscribe 2318
Remarks: start load; COL: 2.200"; 41,800 cup
63 Sierra SP Hodgdon Benchmark Subscribe 2601
Remarks: max load; COL: 2.200"; 50,500 cup
63 Sierra SP Hodgdon H-322 Subscribe 2240
Remarks: start load; COL: 2.200"; 38,100 cup
63 Sierra SP Hodgdon H-322 Subscribe 2482
Remarks: max load; COL: 2.200"; 48,400 cup
63 Sierra SP IMR IMR-4198 Subscribe 2473
Remarks: start load; COL: 2.200"; 48,100 psi
63 Sierra SP IMR IMR-4198 Subscribe 2608
Remarks: max load; COL: 2.200"; 53,500 psi
63 Sierra SP Hodgdon H-4198 Subscribe 2294
Remarks: start load; COL: 2.200"; 33,600 cup
63 Sierra SP Hodgdon H-4198 Subscribe 2572
Remarks: max load; COL: 2.200"; 44,600 cup
69 Sierra HPBT IMR IMR-4320 Subscribe 2218
Remarks: start load; COL: 2.235"; 43,500 psi
69 Sierra HPBT IMR IMR-4320 Subscribe 2471
Remarks: max load; COL: 2.235"; 53,100 psi
69 Sierra HPBT IMR IMR-4064 Subscribe 2227
Remarks: start load; COL: 2.235"; 42,200 psi
69 Sierra HPBT IMR IMR-4064 Subscribe 2435
Remarks: max load; compressed; COL: 2.235"; 50,900 psi
69 Sierra HPBT IMR IMR-4895 Subscribe 2393
Remarks: start load; COL: 2.235"; 44,600 psi
69 Sierra HPBT IMR IMR-4895 Subscribe 2608
Remarks: max load; compressed; COL: 2.235"; 53,600 psi
69 Sierra HPBT IMR IMR-8208 XBR Subscribe 2168
Remarks: start load; COL: 2.235"; 42,200 psi
69 Sierra HPBT IMR IMR-8208 XBR Subscribe 2515
Remarks: max load; COL: 2.235"; 52,900 psi
69 Sierra HPBT IMR IMR-3031 Subscribe 2277
Remarks: start load; COL: 2.235"; 42,900 psi
69 Sierra HPBT IMR IMR-3031 Subscribe 2476
Remarks: max load; COL: 2.235"; 52,800 psi
69 Sierra HPBT IMR IMR-4198 Subscribe 2389
Remarks: start load; COL: 2.235"; 46,300 psi
69 Sierra HPBT IMR IMR-4198 Subscribe 2489
Remarks: max load; COL: 2.235"; 52,300 psi
70 Speer SP IMR IMR-4320 Subscribe 1891
Remarks: start load; COL: 2.140"; 38,200 psi
70 Speer SP IMR IMR-4320 Subscribe 2337
Remarks: max load; COL: 2.140"; 52,900 psi
70 Speer SP IMR IMR-4064 Subscribe 1861
Remarks: start load; COL: 2.140"; 42,000 psi
70 Speer SP IMR IMR-4064 Subscribe 2325
Remarks: max load; compressed; COL: 2.140"; 53,300 psi
70 Speer SP IMR IMR-4895 Subscribe 1943
Remarks: start load; COL: 2.140"; 45,700 psi
70 Speer SP IMR IMR-4895 Subscribe 2495
Remarks: max load; compressed; COL: 2.140"; 52,300 psi
70 Speer SP IMR IMR-8208 XBR Subscribe 2051
Remarks: start load; COL: 2.140"; 44,100 psi
70 Speer SP IMR IMR-8208 XBR Subscribe 2201
Remarks: max load; COL: 2.140"; 52,800 psi
70 Speer SP IMR IMR-3031 Subscribe 2029
Remarks: start load; COL: 2.140"; 47,200 psi
70 Speer SP IMR IMR-3031 Subscribe 2270
Remarks: max load; COL: 2.140"; 50,900 psi