Wt. Bullet Powder Manufacturer Powder Charge Velocity (FPS)
30 Barnes VG IMR IMR-8208 XBR Subscribe 3234
Remarks: start load; COL: 2.040"; 34,900 psi
30 Barnes VG IMR IMR-8208 XBR Subscribe 3522
Remarks: max load; compressed; COL: 2.040"; 42,700 psi
30 Barnes VG Hodgdon Benchmark Subscribe 3332
Remarks: start load; COL: 2.040"; 35,500 psi
30 Barnes VG Hodgdon Benchmark Subscribe 3628
Remarks: max load; compressed; COL: 2.040"; 44,200 psi
30 Barnes VG Hodgdon H-322 Subscribe 3535
Remarks: start load; COL: 2.040"; 40,300 psi
30 Barnes VG Hodgdon H-322 Subscribe 3817
Remarks: max load; compressed; COL: 2.040"; 49,400 psi
30 Barnes VG IMR IMR-4198 Subscribe 3412
Remarks: start load; COL: 2.040"; 37,200 psi
30 Barnes VG IMR IMR-4198 Subscribe 3755
Remarks: max load; COL: 2.040"; 48,900 psi
30 Barnes VG Hodgdon H-4198 Subscribe 3500
Remarks: start load; COL: 2.040"; 37,400 psi
30 Barnes VG Hodgdon H-4198 Subscribe 3817
Remarks: max load; COL: 2.040"; 48,500 psi
30 Barnes VG IMR IMR-4227 Subscribe 3268
Remarks: start load; COL: 2.040"; 40,000 psi
30 Barnes VG IMR IMR-4227 Subscribe 3567
Remarks: max load; COL: 2.040"; 48,400 psi
35 Hornady V-Max IMR IMR-8208 XBR Subscribe 3181
Remarks: start load; COL: 2.025"; 32,000 psi
35 Hornady V-Max IMR IMR-8208 XBR Subscribe 3464
Remarks: max load; compressed; COL: 2.025"; 40,500 psi
35 Hornady V-Max Hodgdon Benchmark Subscribe 3138
Remarks: start load; COL: 2.025"; 33,700 cup
35 Hornady V-Max Hodgdon Benchmark Subscribe 3368
Remarks: max load; compressed; COL: 2.025"; 40,900 cup
35 Hornady V-Max Hodgdon H-322 Subscribe 3316
Remarks: start load; COL: 2.025"; 36,500 cup
35 Hornady V-Max Hodgdon H-322 Subscribe 3591
Remarks: max load; compressed; COL: 2.025"; 45,600 cup
35 Hornady V-Max IMR IMR-4198 Subscribe 3252
Remarks: start load; COL: 2.025"; 34,300 psi
35 Hornady V-Max IMR IMR-4198 Subscribe 3659
Remarks: max load; COL: 2.025"; 47,500 psi
35 Hornady V-Max Hodgdon H-4198 Subscribe 3366
Remarks: start load; COL: 2.025"; 36,500 cup
35 Hornady V-Max Hodgdon H-4198 Subscribe 3591
Remarks: max load; COL: 2.025"; 43,300 cup
35 Hornady V-Max IMR IMR-4227 Subscribe 3195
Remarks: start load; COL: 2.025"; 38,500 psi
35 Hornady V-Max IMR IMR-4227 Subscribe 3500
Remarks: max load; COL: 2.025"; 46,500 psi
35 Hornady V-Max Hodgdon H-4227 Subscribe 3095
Remarks: start load; COL: 2.025"; 38,100 cup
35 Hornady V-Max Hodgdon H-4227 Subscribe 3342
Remarks: max load; COL: 2.025"; 43,000 cup
35 Nosler BT LF IMR IMR-8208 XBR Subscribe 3096
Remarks: start load; COL: 2.130"; 32,500 psi
35 Nosler BT LF IMR IMR-8208 XBR Subscribe 3516
Remarks: max load; compressed; COL: 2.130"; 42,200 psi
35 Nosler BT LF Hodgdon Benchmark Subscribe 3316
Remarks: start load; COL: 2.130"; 34,600 psi
35 Nosler BT LF Hodgdon Benchmark Subscribe 3665
Remarks: max load; compressed; COL: 2.130"; 48,600 psi
35 Nosler BT LF Hodgdon H-322 Subscribe 3290
Remarks: start load; COL: 2.130"; 39,700 psi
35 Nosler BT LF Hodgdon H-322 Subscribe 3527
Remarks: max load; COL: 2.130"; 47,600 psi
35 Nosler BT LF IMR IMR-4198 Subscribe 3220
Remarks: start load; COL: 2.130"; 36,800 psi
35 Nosler BT LF IMR IMR-4198 Subscribe 3539
Remarks: max load; COL: 2.130"; 47,800 psi
35 Nosler BT LF Hodgdon H-4198 Subscribe 3472
Remarks: start load; COL: 2.130"; 44,800 psi
35 Nosler BT LF Hodgdon H-4198 Subscribe 3612
Remarks: max load; COL: 2.130"; 47,300 psi
36 Barnes VG FB Hodgdon H-335 Subscribe 3293
Remarks: start load; COL: 2.150"; 43,000 psi
36 Barnes VG FB Hodgdon H-335 Subscribe 3472
Remarks: max load; COL: 2.150"; 48,700 psi
36 Barnes VG FB IMR IMR-8208 XBR Subscribe 3144
Remarks: start load; COL: 2.150"; 36,700 psi
36 Barnes VG FB IMR IMR-8208 XBR Subscribe 3582
Remarks: max load; compressed; COL: 2.150"; 40,400 psi
36 Barnes VG FB IMR IMR-3031 Subscribe 3147
Remarks: start load; COL: 2.150"; 40,700 psi
36 Barnes VG FB IMR IMR-3031 Subscribe 3356
Remarks: max load; compressed; COL: 2.150"; 47,000 psi
36 Barnes VG FB Hodgdon Benchmark Subscribe 3178
Remarks: start load; COL: 2.150"; 38,500 psi
36 Barnes VG FB Hodgdon Benchmark Subscribe 3471
Remarks: max load; compressed; COL: 2.150"; 48,300 psi
36 Barnes VG FB Hodgdon H-322 Subscribe 3331
Remarks: start load; COL: 2.150"; 41,400 psi
36 Barnes VG FB Hodgdon H-322 Subscribe 3535
Remarks: max load; COL: 2.150"; 47,500 psi
36 Barnes VG FB IMR IMR-4198 Subscribe 3199
Remarks: start load; COL: 2.150"; 40,000 psi
36 Barnes VG FB IMR IMR-4198 Subscribe 3433
Remarks: max load; COL: 2.150"; 48,100 psi
36 Barnes VG FB Hodgdon H-4198 Subscribe 3277
Remarks: start load; COL: 2.150"; 40,500 psi
36 Barnes VG FB Hodgdon H-4198 Subscribe 3470
Remarks: max load; COL: 2.150"; 46,700 psi
40 Sierra HP Hodgdon H-335 Subscribe 3125
Remarks: start load; COL: 2.125"; 38,400 cup
40 Sierra HP Hodgdon H-335 Subscribe 3371
Remarks: max load; COL: 2.125"; 44,600 cup
40 Sierra HP Hodgdon H-4895 Subscribe 2572
Remarks: start load; COL: 2.125"; 23,300 cup
40 Sierra HP Hodgdon H-4895 Subscribe 3133
Remarks: max load; compressed; COL: 2.125"; 34,200 cup
40 Sierra HP IMR IMR-8208 XBR Subscribe 3049
Remarks: start load; COL: 2.125"; 30,400 psi
40 Sierra HP IMR IMR-8208 XBR Subscribe 3452
Remarks: max load; compressed; COL: 2.125"; 42,800 psi
40 Sierra HP Hodgdon Benchmark Subscribe 3110
Remarks: start load; COL: 2.125"; 34,800 cup
40 Sierra HP Hodgdon Benchmark Subscribe 3303
Remarks: max load; COL: 2.125"; 40,700 cup
40 Sierra HP Hodgdon H-322 Subscribe 2966
Remarks: start load; COL: 2.125"; 31,700 cup
40 Sierra HP Hodgdon H-322 Subscribe 3313
Remarks: max load; COL: 2.125"; 44,000 cup
40 Sierra HP IMR IMR-4198 Subscribe 3226
Remarks: start load; COL: 2.125"; 36,300 psi
40 Sierra HP IMR IMR-4198 Subscribe 3583
Remarks: max load; compressed; COL: 2.125"; 48,700 psi
40 Sierra HP Hodgdon H-4198 Subscribe 3201
Remarks: start load; COL: 2.125"; 35,200 cup
40 Sierra HP Hodgdon H-4198 Subscribe 3480
Remarks: max load; COL: 2.125"; 45,700 cup
40 Sierra HP IMR IMR-4227 Subscribe 2984
Remarks: start load; COL: 2.125"; 38,100 psi
40 Sierra HP IMR IMR-4227 Subscribe 3240
Remarks: max load; COL: 2.125"; 45,200 psi
45 Speer SP Winchester W-748 Subscribe 3210
Remarks: max load; COL: 2.130"; 41,000 cup
45 Speer SP Hodgdon BL-C(2) Subscribe 2774
Remarks: start load; COL: 2.130"; 28,100 cup
45 Speer SP Hodgdon BL-C(2) Subscribe 3100
Remarks: max load; COL: 2.130"; 37,400 cup
45 Speer SP IMR IMR-4895 Subscribe 2829
Remarks: start load; COL: 2.130"; 33,100 psi
45 Speer SP IMR IMR-4895 Subscribe 3134
Remarks: max load; compressed; COL: 2.130"; 42,800 psi
45 Speer SP Hodgdon H-335 Subscribe 2962
Remarks: start load; COL: 2.130"; 36,500 cup
45 Speer SP Hodgdon H-335 Subscribe 3252
Remarks: max load; COL: 2.130"; 46,200 cup
45 Speer SP Hodgdon H-4895 Subscribe 2510
Remarks: start load; COL: 2.130"; 25,000 cup
45 Speer SP Hodgdon H-4895 Subscribe 3080
Remarks: max load; compressed; COL: 2.130"; 35,900 cup
45 Speer SP IMR IMR-8208 XBR Subscribe 3121
Remarks: start load; COL: 2.130"; 38,700 psi
45 Speer SP IMR IMR-8208 XBR Subscribe 3327
Remarks: max load; COL: 2.130"; 47,200 psi
45 Speer SP IMR IMR-3031 Subscribe 2806
Remarks: start load; COL: 2.130"; 31,000 psi
45 Speer SP IMR IMR-3031 Subscribe 3226
Remarks: max load; compressed; COL: 2.130"; 45,800 psi
45 Speer SP Hodgdon Benchmark Subscribe 3092
Remarks: start load; COL: 2.130"; 39,700 cup
45 Speer SP Hodgdon Benchmark Subscribe 3290
Remarks: max load; COL: 2.130"; 44,900 cup
45 Speer SP Hodgdon H-322 Subscribe 2914
Remarks: start load; COL: 2.130"; 34,600 cup
45 Speer SP Hodgdon H-322 Subscribe 3173
Remarks: max load; COL: 2.130"; 43,600 cup
45 Speer SP IMR IMR-4198 Subscribe 3083
Remarks: start load; COL: 2.130"; 40,600 psi
45 Speer SP IMR IMR-4198 Subscribe 3311
Remarks: max load; COL: 2.130"; 47,600 psi
45 Speer SP Hodgdon H-4198 Subscribe 3011
Remarks: start load; COL: 2.130"; 33,400 cup
45 Speer SP Hodgdon H-4198 Subscribe 3315
Remarks: max load; COL: 2.130"; 44,800 cup
45 Speer SP Hodgdon H-4227 Subscribe 2259
Remarks: start load; COL: 2.130"; 24,300 cup
45 Speer SP Hodgdon H-4227 Subscribe 2863
Remarks: max load; COL: 2.130"; 46,100 cup
50 Hornady SP Hodgdon CFE 223 Subscribe 2970
Remarks: start load; COL: 2.130"; 35,200 psi
50 Hornady SP Hodgdon CFE 223 Subscribe 3268
Remarks: max load; COL: 2.130"; 47,600 psi
50 Hornady SP Hodgdon Varget Subscribe 2884
Remarks: start load; COL: 2.130"; 33,600 cup
50 Hornady SP Hodgdon Varget Subscribe 3114
Remarks: max load; compressed COL: 2.130"; 40,600 cup
50 Hornady SP IMR IMR-4320 Subscribe 2802
Remarks: start load; COL: 2.130"; 36,900 psi
50 Hornady SP IMR IMR-4320 Subscribe 3100
Remarks: max load; compressed COL: 2.130"; 47,600 psi
50 Hornady SP IMR IMR-4064 Subscribe 2711
Remarks: start load; COL: 2.130"; 33,500 psi
50 Hornady SP IMR IMR-4064 Subscribe 3065
Remarks: max load; compressed COL: 2.130"; 46,200 psi
50 Hornady SP Winchester W-748 Subscribe 2980
Remarks: max load; COL: 2.130"; 38,000 cup
50 Hornady SP Hodgdon BL-C(2) Subscribe 2693
Remarks: start load; COL: 2.130"; 25,500 cup
50 Hornady SP Hodgdon BL-C(2) Subscribe 3000
Remarks: max load; COL: 2.130"; 38,600 cup
50 Hornady SP IMR IMR-4895 Subscribe 2845
Remarks: start load; COL: 2.130"; 37,800 psi
50 Hornady SP IMR IMR-4895 Subscribe 3106
Remarks: max load; compressed COL: 2.130"; 47,400 psi
50 Hornady SP Hodgdon H-335 Subscribe 2861
Remarks: start load; COL: 2.130"; 37,100 cup
50 Hornady SP Hodgdon H-335 Subscribe 3120
Remarks: max load; COL: 2.130"; 45,700 cup
50 Hornady SP Hodgdon H-4895 Subscribe 2466
Remarks: start load; COL: 2.130"; 23,900 cup
50 Hornady SP Hodgdon H-4895 Subscribe 3022
Remarks: max load; compressed; COL: 2.130"; 36,500 cup
50 Hornady SP IMR IMR-8208 XBR Subscribe 3006
Remarks: start load; COL: 2.130"; 39,200 psi
50 Hornady SP IMR IMR-8208 XBR Subscribe 3201
Remarks: max load; COL: 2.130"; 47,100 psi
50 Hornady SP IMR IMR-3031 Subscribe 2740
Remarks: start load; COL: 2.130"; 32,000 psi
50 Hornady SP IMR IMR-3031 Subscribe 3156
Remarks: max load; compressed; COL: 2.130"; 47,800 psi
50 Hornady SP Hodgdon Benchmark Subscribe 2994
Remarks: start load; COL: 2.130"; 39,200 cup
50 Hornady SP Hodgdon Benchmark Subscribe 3168
Remarks: max load; COL: 2.130"; 45,800 cup
50 Hornady SP Hodgdon H-322 Subscribe 2810
Remarks: start load; COL: 2.130"; 33,300 cup
50 Hornady SP Hodgdon H-322 Subscribe 3079
Remarks: max load; COL: 2.130"; 43,200 cup
50 Hornady SP IMR IMR-4198 Subscribe 2850
Remarks: start load; COL: 2.130"; 37,100 psi
50 Hornady SP IMR IMR-4198 Subscribe 3152
Remarks: max load; COL: 2.130"; 49,000 psi
50 Hornady SP Hodgdon H-4198 Subscribe 2890
Remarks: start load; COL: 2.130"; 34,000 cup
50 Hornady SP Hodgdon H-4198 Subscribe 3160
Remarks: max load; COL: 2.130"; 44,200 cup
53 Hornady HP Hodgdon CFE 223 Subscribe 2904
Remarks: start load; COL: 2.140"; 35,700 psi
53 Hornady HP Hodgdon CFE 223 Subscribe 3211
Remarks: max load; COL: 2.140"; 48,800 psi
53 Hornady HP Hodgdon Varget Subscribe 2863
Remarks: start load; COL: 2.140"; 33,500 cup
53 Hornady HP Hodgdon Varget Subscribe 3097
Remarks: max load; compressed; COL: 2.140"; 42,700 cup
53 Hornady HP IMR IMR-4320 Subscribe 2670
Remarks: start load; COL: 2.140"; 34,600 psi
53 Hornady HP IMR IMR-4320 Subscribe 3033
Remarks: max load; COL: 2.140"; 48,600 psi
53 Hornady HP IMR IMR-4064 Subscribe 2662
Remarks: start load; COL: 2.140"; 33,300 psi
53 Hornady HP IMR IMR-4064 Subscribe 3024
Remarks: max load; compressed; COL: 2.140"; 47,400 psi
53 Hornady HP Winchester W-748 Subscribe 2855
Remarks: max load; COL: 2.140"; 36,000 cup
53 Hornady HP Hodgdon BL-C(2) Subscribe 2639
Remarks: start load; COL: 2.140"; 29,300 cup
53 Hornady HP Hodgdon BL-C(2) Subscribe 2967
Remarks: max load; COL: 2.140"; 42,100 cup
53 Hornady HP IMR IMR-4895 Subscribe 2684
Remarks: start load; COL: 2.140"; 34,400 psi
53 Hornady HP IMR IMR-4895 Subscribe 3051
Remarks: max load; compressed; COL: 2.140"; 48,200 psi
53 Hornady HP Hodgdon H-335 Subscribe 2748
Remarks: start load; COL: 2.140"; 35,900 cup
53 Hornady HP Hodgdon H-335 Subscribe 3006
Remarks: max load; COL: 2.140"; 46,000 cup
53 Hornady HP Hodgdon H-4895 Subscribe 2585
Remarks: start load; COL: 2.140"; 27,800 cup
53 Hornady HP Hodgdon H-4895 Subscribe 3043
Remarks: max load; compressed; COL: 2.140"; 41,600 cup
53 Hornady HP IMR IMR-8208 XBR Subscribe 2844
Remarks: start load; COL: 2.140"; 36,100 psi
53 Hornady HP IMR IMR-8208 XBR Subscribe 3117
Remarks: max load; COL: 2.140"; 48,200 psi
53 Hornady HP IMR IMR-3031 Subscribe 2693
Remarks: start load; COL: 2.140"; 33,200 psi
53 Hornady HP IMR IMR-3031 Subscribe 3064
Remarks: max load; compressed; COL: 2.140"; 47,600 psi
53 Hornady HP Hodgdon Benchmark Subscribe 2852
Remarks: start load; COL: 2.140"; 38,800 cup
53 Hornady HP Hodgdon Benchmark Subscribe 3063
Remarks: max load; COL: 2.140"; 45,500 cup
53 Hornady HP Hodgdon H-322 Subscribe 2724
Remarks: start load; COL: 2.140"; 34,900 cup
53 Hornady HP Hodgdon H-322 Subscribe 3005
Remarks: max load; COL: 2.140"; 46,000 cup
53 Hornady HP IMR IMR-4198 Subscribe 2742
Remarks: start load; COL: 2.140"; 36,500 psi
53 Hornady HP IMR IMR-4198 Subscribe 3025
Remarks: max load; COL: 2.140"; 47,900 psi
53 Hornady HP Hodgdon H-4198 Subscribe 2800
Remarks: start load; COL: 2.140"; 35,300 cup
53 Hornady HP Hodgdon H-4198 Subscribe 3038
Remarks: max load; COL: 2.140"; 45,500 cup
55 Speer SP Hodgdon CFE 223 Subscribe 2894
Remarks: start load; COL: 2.130"; 35,000 psi
55 Speer SP Hodgdon CFE 223 Subscribe 3174
Remarks: max load; COL: 2.130"; 47,600 psi
55 Speer SP Hodgdon Varget Subscribe 2860
Remarks: start load; COL: 2.130"; 34,500 cup
55 Speer SP Hodgdon Varget Subscribe 3095
Remarks: max load; compressed; COL: 2.130"; 43,000 cup
55 Speer SP IMR IMR-4320 Subscribe 2647
Remarks: start load; COL: 2.130"; 34,500 psi
55 Speer SP IMR IMR-4320 Subscribe 2961
Remarks: max load; compressed; COL: 2.130"; 46,000 psi
55 Speer SP IMR IMR-4064 Subscribe 2739
Remarks: start load; COL: 2.130"; 36,500 psi
55 Speer SP IMR IMR-4064 Subscribe 2954
Remarks: max load; compressed; COL: 2.130"; 44,400 psi
55 Speer SP Winchester W-748 Subscribe 2900
Remarks: max load; COL: 2.130"; 38,000 cup
55 Speer SP Hodgdon BL-C(2) Subscribe 2625
Remarks: start load; COL: 2.130"; 28,200 cup
55 Speer SP Hodgdon BL-C(2) Subscribe 2876
Remarks: max load; COL: 2.130"; 35,400 cup
55 Speer SP IMR IMR-4895 Subscribe 2632
Remarks: start load; COL: 2.130"; 32,700 psi
55 Speer SP IMR IMR-4895 Subscribe 3017
Remarks: max load; compressed; COL: 2.130"; 47,300 psi
55 Speer SP Hodgdon H-335 Subscribe 2776
Remarks: start load; COL: 2.130"; 35,300 cup
55 Speer SP Hodgdon H-335 Subscribe 3037
Remarks: max load; COL: 2.130"; 45,600 cup
55 Speer SP Hodgdon H-4895 Subscribe 2569
Remarks: start load; COL: 2.130"; 28,900 cup
55 Speer SP Hodgdon H-4895 Subscribe 3023
Remarks: max load; compressed; COL: 2.130"; 39,900 cup
55 Speer SP IMR IMR-8208 XBR Subscribe 2905
Remarks: start load; COL: 2.130"; 38,400 psi
55 Speer SP IMR IMR-8208 XBR Subscribe 3120
Remarks: max load; compressed; COL: 2.130"; 48,500 psi
55 Speer SP IMR IMR-3031 Subscribe 2687
Remarks: start load; COL: 2.130"; 33,500 psi
55 Speer SP IMR IMR-3031 Subscribe 3004
Remarks: max load; compressed; COL: 2.130"; 46,300 psi
55 Speer SP Hodgdon Benchmark Subscribe 2843
Remarks: start load; COL: 2.130"; 38,100 cup
55 Speer SP Hodgdon Benchmark Subscribe 3052
Remarks: max load; COL: 2.130"; 45,100 cup
55 Speer SP Hodgdon H-322 Subscribe 2654
Remarks: start load; COL: 2.130"; 31,600 cup
55 Speer SP Hodgdon H-322 Subscribe 2953
Remarks: max load; COL: 2.130"; 45,100 cup
55 Speer SP IMR IMR-4198 Subscribe 2722
Remarks: start load; COL: 2.130"; 35,900 psi
55 Speer SP IMR IMR-4198 Subscribe 3017
Remarks: max load; COL: 2.130"; 47,700 psi
55 Speer SP Hodgdon H-4198 Subscribe 2733
Remarks: start load; COL: 2.130"; 33,400 cup
55 Speer SP Hodgdon H-4198 Subscribe 3017
Remarks: max load; COL: 2.130"; 45,300 cup
60 Hornady V-Max Hodgdon CFE 223 Subscribe 2652
Remarks: start load; COL: 2.160"; 33,300 psi
60 Hornady V-Max Hodgdon CFE 223 Subscribe 2972
Remarks: max load; COL: 2.160"; 47,900 psi
60 Hornady V-Max Hodgdon Varget Subscribe 2734
Remarks: start load; COL: 2.160"; 36,600 cup
60 Hornady V-Max Hodgdon Varget Subscribe 2906
Remarks: max load; compressed; COL: 2.160"; 42,800 cup
60 Hornady V-Max IMR IMR-4320 Subscribe 2408
Remarks: start load; COL: 2.160"; 32,400 psi
60 Hornady V-Max IMR IMR-4320 Subscribe 2805
Remarks: max load; compressed; COL: 2.160"; 47,800 psi
60 Hornady V-Max IMR IMR-4064 Subscribe 2530
Remarks: start load; COL: 2.160"; 34,500 psi
60 Hornady V-Max IMR IMR-4064 Subscribe 2862
Remarks: max load; compressed; COL: 2.160"; 47,800 psi
60 Hornady V-Max Hodgdon BL-C(2) Subscribe 2590
Remarks: start load; COL: 2.160"; 33,200 cup
60 Hornady V-Max Hodgdon BL-C(2) Subscribe 2803
Remarks: max load; COL: 2.160"; 44,000 cup
60 Hornady V-Max IMR IMR-4895 Subscribe 2573
Remarks: start load; COL: 2.160"; 36,200 psi
60 Hornady V-Max IMR IMR-4895 Subscribe 2907
Remarks: max load; compressed; COL: 2.160"; 49,100 psi
60 Hornady V-Max Hodgdon H-335 Subscribe 2602
Remarks: start load; COL: 2.160"; 34,400 cup
60 Hornady V-Max Hodgdon H-335 Subscribe 2759
Remarks: max load; COL: 2.160"; 42,900 cup
60 Hornady V-Max Hodgdon H-4895 Subscribe 2802
Remarks: start load; COL: 2.160"; 38,500 cup
60 Hornady V-Max Hodgdon H-4895 Subscribe 2937
Remarks: max load; compressed; COL: 2.160"; 43,500 cup
60 Hornady V-Max IMR IMR-8208 XBR Subscribe 2737
Remarks: start load; COL: 2.160"; 39,200 psi
60 Hornady V-Max IMR IMR-8208 XBR Subscribe 2920
Remarks: max load; COL: 2.160"; 48,200 psi
60 Hornady V-Max IMR IMR-3031 Subscribe 2476
Remarks: start load; COL: 2.160"; 32,900 psi
60 Hornady V-Max IMR IMR-3031 Subscribe 2838
Remarks: max load; compressed; COL: 2.160"; 48,700 psi
60 Hornady V-Max Hodgdon Benchmark Subscribe 2627
Remarks: start load; COL: 2.160"; 35,900 cup
60 Hornady V-Max Hodgdon Benchmark Subscribe 2805
Remarks: max load; COL: 2.160"; 42,800 cup
60 Hornady V-Max Hodgdon H-322 Subscribe 2592
Remarks: start load; COL: 2.160"; 34,800 cup
60 Hornady V-Max Hodgdon H-322 Subscribe 2818
Remarks: max load; COL: 2.160"; 42,900 cup
60 Hornady V-Max IMR IMR-4198 Subscribe 2552
Remarks: start load; COL: 2.160"; 37,100 psi
60 Hornady V-Max IMR IMR-4198 Subscribe 2832
Remarks: max load; COL: 2.160"; 48,400 psi
60 Hornady V-Max Hodgdon H-4198 Subscribe 2633
Remarks: start load; COL: 2.160"; 36,100 cup
60 Hornady V-Max Hodgdon H-4198 Subscribe 2771
Remarks: max load; COL: 2.160"; 42,400 cup
63 Sierra SP Hodgdon CFE 223 Subscribe 2724
Remarks: start load; COL: 2.125"; 36,500 psi
63 Sierra SP Hodgdon CFE 223 Subscribe 2986
Remarks: max load; COL: 2.125"; 48,900 psi
63 Sierra SP Hodgdon Varget Subscribe 2718
Remarks: start load; COL: 2.125"; 34,500 cup
63 Sierra SP Hodgdon Varget Subscribe 2935
Remarks: max load; compressed; COL: 2.125"; 43,800 cup
63 Sierra SP IMR IMR-4320 Subscribe 2450
Remarks: start load; COL: 2.125"; 34,900 psi
63 Sierra SP IMR IMR-4320 Subscribe 2774
Remarks: max load; compressed; COL: 2.125"; 48,400 psi
63 Sierra SP IMR IMR-4064 Subscribe 2490
Remarks: start load; COL: 2.125"; 34,400 psi
63 Sierra SP IMR IMR-4064 Subscribe 2812
Remarks: max load; compressed; COL: 2.125"; 47,700 psi
63 Sierra SP Hodgdon BL-C(2) Subscribe 2626
Remarks: start load; COL: 2.125"; 32,600 cup
63 Sierra SP Hodgdon BL-C(2) Subscribe 2864
Remarks: max load; COL: 2.125"; 43,200 cup
63 Sierra SP IMR IMR-4895 Subscribe 2485
Remarks: start load; COL: 2.125"; 35,400 psi
63 Sierra SP IMR IMR-4895 Subscribe 2827
Remarks: max load; compressed; COL: 2.125"; 49,200 psi
63 Sierra SP Hodgdon H-335 Subscribe 2672
Remarks: start load; COL: 2.125"; 37,800 cup
63 Sierra SP Hodgdon H-335 Subscribe 2830
Remarks: max load; COL: 2.125"; 45,700 cup
63 Sierra SP Hodgdon H-4895 Subscribe 2537
Remarks: start load; COL: 2.125"; 30,300 cup
63 Sierra SP Hodgdon H-4895 Subscribe 2965
Remarks: max load; compressed; COL: 2.125"; 45,500 cup
63 Sierra SP IMR IMR-8208 XBR Subscribe 2681
Remarks: start load; COL: 2.125"; 39,300 psi
63 Sierra SP IMR IMR-8208 XBR Subscribe 2865
Remarks: max load; COL: 2.125"; 48,400 psi
63 Sierra SP IMR IMR-3031 Subscribe 2527
Remarks: start load; COL: 2.125"; 35,400 psi
63 Sierra SP IMR IMR-3031 Subscribe 2809
Remarks: max load; compressed; COL: 2.125"; 48,400 psi
63 Sierra SP Hodgdon Benchmark Subscribe 2732
Remarks: start load; COL: 2.125"; 39,000 cup
63 Sierra SP Hodgdon Benchmark Subscribe 2903
Remarks: max load; COL: 2.125"; 45,700 cup
63 Sierra SP Hodgdon H-322 Subscribe 2531
Remarks: start load; COL: 2.125"; 33,600 cup
63 Sierra SP Hodgdon H-322 Subscribe 2780
Remarks: max load; COL: 2.125"; 44,400 cup
63 Sierra SP IMR IMR-4198 Subscribe 2519
Remarks: start load; COL: 2.125"; 37,600 psi
63 Sierra SP IMR IMR-4198 Subscribe 2759
Remarks: max load; COL: 2.125"; 48,500 psi
63 Sierra SP Hodgdon H-4198 Subscribe 2597
Remarks: start load; COL: 2.125"; 36,200 cup
63 Sierra SP Hodgdon H-4198 Subscribe 2793
Remarks: max load; COL: 2.125"; 43,800 cup